压水堆核电厂非能动余热排出系统对比研究
2017-07-01周科张丹魏宗岚初晓吴皓
周科 张丹 魏宗岚 初晓 吴皓
【摘 要】绝大部分先进压水堆都采用非能动方式导出余热,以提高反应堆的固有安全性。根据非能动余热排出系统的布置方式,一般可分为一次侧余排(S-PRS)和二次侧余排(T-PRS)。本文以AP1000核电厂全厂断电事故为例,分析这两种非能动余排在事故下的响应,为系统设计提供相应的参考。
【关键词】非能动余排;余热;压水堆;对比
Compare of Passive Residual Heat Removal System for Pressurized Water Reactor
ZHOU Ke ZHANG Dan WEI Zong-lan CHU Xiao WU Guang-hao
(.Science and Technology on Reactor System Design Technology Laboratory,Chengdu Sichuan 610213,China)
【Abstract】Passive residual heat removal system (PRHR) is adopted for many of pressurized water reactor,in order of improving inherency safety performance.according the layout of PRS,it can be divided into reactor coolant loop system(direct system,S-PRS) and secondary system (indirect system,T-PRS).Basing on station blackout accident, the thermal hydraulic responds of two kinds system was studied.The result shows that each of system can remove all of reactor residual heat,however,the performance is different,the nuclear power plant show select the appropriate system basing on its design.
【Key words】Passive residual heat removal system;Residual heat;Pressurized water reactor;Comparison
0 引言
在目前的先进反应堆设计中,各国都非常强调非能动安全概念,绝大部分先进压水堆都采用了非能动余热排出系统(PRS)[1],以提高反应堆的固有安全性。主流核电厂的非能动余排系统布置可分为一次侧非能动余热排出系统(S-PRS)(如西屋公司推出的AP1000[2]和中核集团的模块式小型堆ACP100[3])和二次侧非能动余热排出系统(T-PRS)(如中核集团的ACP1000[4]和美国的IRIS[5]、韩国的SMART[6]小堆)等,而法国DCNS开发的Flexblue[7]的水下电厂既采用了S-PRS,也采用了T-PRS。
对于PRS,国内外学者都进行了大量研究[8][9],但缺少对于S-PRS和T-PRS的详细对比研究。随着国内对于非能动核安全监管要求的加强[10],有必要开展相关的研究,为未来的设计提供参考。
1 典型的非能动余排系统
典型的S-PRS见图1.a,主要设计思路是设置一列和蒸汽发生器并联的换热回路,用于事故后得以应急余热导出,该系统包括一台浸入中间热阱(换料水箱)的换热器、一个入口常开阀、两个并联的出口常关阀、和相应的管道仪表组成。
典型的T-PRS布置示例见图1.b,主要設计思路是在SG二回路设置一列和动力转换系统并联的换热回路,专注于事故后余热导出,该系统主设备和一次侧余排相同,主要差异为该系统可能设置补水箱、中间热阱也须单独设置。……