高效液相色谱测定抗坏血酸对映体色谱柱选择
2020-03-31杜瑞关炳峰尹红娜王珂孙茜茜陈世伟
杜瑞 关炳峰 尹红娜 王珂 孙茜茜 陈世伟



摘要[目的]选择L-抗坏血酸和D-异抗坏血酸在高效液相色谱分离中最佳色谱柱。[方法]对比C18柱、HILIC酰胺柱、HILIC聚合物柱、HILIC硅胶柱、氨基柱和氰基柱6种色谱柱填料分析抗坏血酸对映体的分离度和流动相。[结果]HILIC酰胺柱分离度最大,为4.84;其次为氨基柱,分离度为2.80;流动相为0.1%磷酸水和乙腈。[结论]HILIC酰胺柱为分析抗坏血酸对映体的最合适色谱柱填料。
关键词高效液相色谱;L-抗坏血酸;D-异抗坏血酸;色谱柱
中图分类号O657.7+2文献标识码A
文章编号0517-6611(2020)04-0196-03
doi:10.3969/j.issn.0517-6611.2020.04.057
开放科学(资源服务)标识码(OSID):
Determination of Ascorbic Acid Enantiomer Column by High Performance Liquid Chromatography
DU Rui,GUAN Bing-feng,YIN Hong-na et al(Henan Commerce Science Institute Co.,Ltd.,Zhengzhou,Henan 450002)
Abstract[Objective]L-ascorbic acid and D-ascorbic acid were selected as the best chromatographic columns for HPLC separation.[Method]The C18 column,HILIC amide column,HILIC polymer column,HILIC silica column,amino column and cyano column were compared to analyze the ascorbic acid enantiomer resolution and mobile phase.[Result]The highest resolution of the HILIC amide column was 4.84;the second was the amino column with a resolution of 2.80;the mobile phase was 0.1% phosphoric acid water and acetonitrile.[Conclusion]HILIC amide column is the most suitable column packing for the analysis of ascorbic acid enantiomers.
Key wordsHPLC;L-ascorbic acid;D-isoascorbic acid;Chromatographic column
L-抗壞血酸(L-ascorbic acid)又称维生素C(Vitamin C),学名L-3-氧代苏己糖醛酸内酯[1]。L-抗坏血酸在人体内不能合成,主要存在于蔬菜和水果中,天然具有抗氧化性质,是一种营养强化剂和食品添加剂,广泛用于食品加工和保健品行业中[2-3]。D-异抗坏血酸(D-isoascorbic acid)是L-抗坏血酸的对映异构体,与L-抗坏血酸化学性质相似,但生理活性仅有L-抗坏血酸的1/20[4]。D-异抗坏血酸作为食品抗氧化剂和肉制品的防腐助色剂[2,5-6],但摄入过多会造成白细胞的抗病能力下降,使人体受到伤害[7]。
由于L-抗坏血酸、D-异抗坏血酸生理活性不同,因此对抗坏血酸对映异构体分析十分重要。在手性分析中,常用的分离手段有毛细管电泳法[8-10]和高效液相色谱法[11-15]。毛细管电泳分离方法虽然有很高的手性分析能力,但与HPLC相比柱容量小,造成不宜大体积高浓度进样;并且在食品安全检测方面,毛细管电泳没有高效液相色谱普及率高。笔者采用HPLC法测定抗坏血酸对映体,考察不同色谱填料(C18、HILIC、NH2、CN)对抗坏血酸对映体分离的影响。……