APP下载

中空纤维支撑液膜结合气相色谱测定肉中挥发性脂肪酸

2012-08-07陈海桂王云帆孙金辉赵国华

食品科学 2012年24期
关键词:重庆

陈海桂,王云帆,2,孙金辉,赵国华,3,*

(1.西南大学食品科学学院,重庆 400716; 2.重庆科技大学化学化工学院,重庆 401331;3.重庆市农产品加工技术重点实验室,重庆 400716)

Recently there has been an increasing interest in the meat quality which is due to the fact that meat is highly associated with health and is a major source of nutrients, such as protein and fat. It is well known that meat quality includes such traits as tenderness, intramuscular fat, water holding capacity, color, texture and freshness. Among these traits,freshness, which plays a crucial role in the acceptability of meat both for consumers and food industries, has become a most important attribute of meat quality.

The meat suffers critical deterioration as it is exposed to air which causes the decreasing of freshness. Many factors affect meat freshness which are correlated with postmortem aging, conditions prior to death, sexual maturity, stored temperature and environment. Degradation of protein and lipid in meat during storage is generally attributed to bacterial decay, enzymatic degradation and lipid oxidation. When fresh meat was stored in room environment, polyamines and amino acids was produced initially by enzymatic degradation serving as nutrients for bacteria, and as a result, the level of bacterial cells increased with the deterioration of meat freshness.

As a result of deterioration, the physic-chemical properties of fresh meat undergo significant changes in various aspects, such as hardness, elasticity, viscosity,dielectric properties, odor, pH and total basic volatile nitrogen(TVB-N) content. Various methods have been applied to assess the meat freshness based on above-mentioned changes,such as gas sensor arrays based on odor[1], potentiometer sensor based on changes of organic compounds and sulf ides[2],cyclic voltammetric system based on electrochemical signals[3], enzymatic sensor based on hypoxanthine[4], and mostly used titration method based on TVB-N.

Volatile fatty acids (VFAs), mainly including acetic,propionic, butyric and valeric acids, are wildly found in various foods. Although always presented in trace amount,VFAs exerted heavy inf luences on the f lavor of plant foods.Yang et al[5]reported that acetic acid and lactic acids were the major VFAs found in fruit juice. Different kinds of VFAs were previously detected in meats and related products.Calkins et al[6]ascribed the goaty flavor of beef to caproic acid. Ranau et al[7]reported that rancid and pungent f lavor of air from pig house were associated with butanoic acid and propanoic acid, respectively. However, changes of VFAs during meat deterioration and its implication for the freshness were not explored up to date.

There are numerous methods to determine VFAs in environmental and biological samples. These include gas chromatography with/without derivatization[8-9]and ion exclusion chromatography[10]. These methods, especially those requiring derivatization of VFAs, are highly time consuming and solvent wasting and are disabled in determining trace amount of VFAs. Hollow f iber supported liquid membrane extraction (HF-SLME) has been utilized as an inexpensive, convenient and effective step in various samples[11]to selectively pre-enrich the trace amount of VFAs prior to chromatographic analysis. The selective extraction mechanism and high enrichment factor of HF-SLME give enough low detection limits and reduce the interference from contaminants.

The purpose of this study was to develop a novel approach using HF-SLME combined with GC to determine VFAs in meat. Meanwhile, changes in VFAs and TVB-N of fresh pork during stored in ambient environment were correlated and variations of VFAs in different meats were investigated.

1 Material and Methods

1.1 Materials and regents

In calibration and validation of the method, fresh pork,beef, mutton, chicken, duck meat and pigeon meat purchased from a local supermarket were used. Fresh pork samples were stored at room environment up to 42 h and a piece of samples was picked out with an interval of 1 h to obtain a series of products with varying freshness[12]. The pH value was determined by adding 10 mL of distilled water to 10 g of meat samples[13]with a pH meter PB10 (Sartorius, Germany).The determination of TVB-N was performed according to the method reported by Cai et al[14].

Acetic acid (100%) was purchased from Germany Merck Co. Ltd.. Propionic acid (99%) and butyric acid(99%) were obtained from Belgium Jansssen Chimica Co. Ltd.. 2-ethylbutyric acid, used as an internal standard,was obtained from Sinma-Aldrich (Steinheim, Germany).Isobutyric acid and isovaleric acid with a purity of 99%, Trin-octyl phosphine oxide (TOPO) and dihexyl ether (DHE)were obtained from Sigma St. Louis, MO, USA. The organic solvent as membrane liquid was prepared by dissolving appropriate amounts of TOPO in DHE. The aqueous solution of 0.1 mol/L NaOH was used as acceptor. All other chemicals were of highest grade commercially available and water obtained by a Milli-Qbiocel system (Millipore, Bedford, MA,USA) was applied throughout the experiment.

Aqueous stock standard solution was prepared for each acid with a concentration of 9.0 mol/L for acetic acid, 5.80 mol/L for propionic acid, 5.40 mol/L for butyric acid, 1.70 mol/L for isobutyric acid, and 1.20 mol/L for isovaleric acid.A working standard solution containing the 5 target analytes was prepared by mixing appropriate volumes of the individual standard stock solution and diluting it with water. An internal standard stock solution containing 2-ethylbutyric acid with 12% formic acid was also prepared. All the stock standard and working solutions were stored at 20 ℃ until used.

1.2 Instruments

GC-2010 instrument (Shimadzu, Japan) equipped with a flame ionization detector. DB-FFAP fused-silica capillary column with free fatty acid phase (30 m × 0.53 mm i.d., 0.50 μm film thickness, Zhonghuida, China). 50/280 Accurel PP polypropylene hollow f iber with a thickness of 50 μm (0.1 μm pore size) and an internal diameter of 280 μm from Membrana GmbH (Wuppertal Germany). BD Micro-Fine Syringes (with a needle of 0.30 mm outer diameter and 8 cm length, 0.5 mL)obtained from BD Consumer Healthcare (via a local pharmacy),and 100 μL pulled point conical glass vials (Agilent, USA).

1.3 Sample preparation

Meat was homogenized with addition of water with a sample/water ratio of 1:60 (g/mL) by a deconcentrator (XHF-D,Xinzhi, China) at 10000 r/min for one minute. The resulting slurry was centrifuged at 3000 r/min for 15 min in a centrifuge(TGL-16G, Anting, China). The obtained supernatant was acidif ied to result a pH of 2 with 2 mol/L HCl and used as the donor of HF-SLME. The free exudate of meat slurry wrapped in 11 cm f ilter paper with a sample/water ratio of 1:3 (g/mL)was directly analyzed by GC as a control.

1.4 Extraction procedure

The extraction was carried out as described by Liu et al[15]with minor modifications. The hollow fiber was cut manually into approximately 16 cm length, and then the lumen of hollow f iber was f lushed and f illed with the acceptor solution by using the BD Micro-Fine Syringe. Afterwards, the f iber was dipped into the membrane liquid for a few seconds to impregnate the pores of the hollow f iber wall forming the organic liquid membrane. After that, the lumen of f iber was slowly f lushed with acceptor solution to remove any organic solvent and air bubbles in the lumen and f illed the acceptor solution completely. Then, the two ends of the fiber were folded and enveloped with a small piece of aluminum foil and sealed f iber was washed away the out surplus membrane liquid by soaking into water for few minutes. This prepared HF-SLME device was fully immersed into the 1.5 mL sample solution in a 2 mL capped vial. The vial was capped and shaken on a shaker for 16 h to perform extraction and enrichment. After extraction, the hollow fiber extraction device was harvested and one of the sealed ends was cut and connected to the needle of a BD Micro-Fine Syringe filled with air, and then the other end was cut and put into the 100 μL pulled point conical glass vial. Next, the syringe plunger was pushed in to flush the acceptor containing the analytes from the fiber lumen into the conical glass vial.Approximately 8-12 μL solution could be harvested, of which 8 μL was transferred into another 100 μL pulled point conical glass vial and 10 μL 1 mol/L HCl was added.Then the vial could be directly for GC system and 1 μL was injected into the GC system for analysis.

1.5 Gas chromatographic analysis

Gas chromatographic separations were carried out using the follow conditions. The temperature of the detector and injector were 240 ℃ and 200 ℃, respectively. The carrier gas was nitrogen with a flow rate of 14.4 mL/min. The oven temperature was programmed at 100 ℃ and kept for 0.5 min,ramped to 180 ℃ by 8 ℃/min for 1.0 min, then further increased to 200 ℃ at 20 ℃/min, and f inally held at 200 ℃ for 5 min. The f low rates of hydrogen, air and nitrogen as makeup gas were 30, 300 mL/min and 20 mL/min, respectively.

1.6 Evaluation of the method

Limits of detection (LOD) and quantification (LOQ)were used to understand the lowest detectable level of each VFA, which were estimated using the classical 3σblankapproach, calculation of limits of detection through analysis of the standard deviation of blank measurements[16].

Validation of the present method was performed using the recovery and reproducibility tests. For the recovery test,the standard 5 VFAs mixture was added into the pork slurry at three levels with known concentrations and subjected to treatment as described above and then analyzed by GC. For reproducibility, both intra-assay and inter-assay reproducibility of standard and samples were determined.The intra-assay reproducibility was obtained by analyzing the same supernatant 10 times on the same day. The inter-assay reproducibility was determined by analyzing the samples on ten different days up to 15 times. In between, the samples were stored at-20 ℃. The precision of the method was expressed in terms of relative standard deviation (RSD).

1.7 Data processing

All experiments were conducted at least thrice. Data were expressed as mean ± standard error, and significant differences between the means of parameters were determined by using the Duncan test (P<0.05). All analyses were conducted using the Origin (Version 8) and SPSS 16.0 statistical software in a compatible PC.

2 Results and Discussion

2.1 Parameters for HF-SLME

In order to determine VFAs mentioned above, several parameters were considered in the assays. There are choices of dilution ratio of sample, pH of donor, concentration of acceptor, type of membrane liquid and extraction time. The extraction parameters previously reported by our group[17]in determination VFAs in serum was directly performed in the present work without further optimization. Alternatively,VFAs extraction was performed with donor pH of 2, liquid membrane of 10% TOPO in DHE and basic acceptor of 0.1 mol/L NaOH for 16 h. Regarding to the dilution ratio of sample, the results in primary experiment suggested a ratio of sample/water of 1:60 (g/mL) in preparation of donor given out acceptable stability of extraction and chromatograms.

2.2 Performance of the method

2.2.1 Chromatogram

The chromatograms of free exudates and acceptors from HF-SLME of standard solution and acidified aqueous supernatant of meat slurry are shown in Fig. 1.

Fig.1 GC chromatograms of mixed fatty acid standards (a), centrifugal supernatant of meat homogenate (b), and its enriched product (c)

The well separated peaks of analytes and internal standard in standard solution chromatogram confirmed the validity of the applied GC procedure and parameters, which allowed easy identification and accurate quantification of VFAs in actual samples. Moreover, the clean chromatogram and the acceptable abundance of the target peaks in the chromatogram of acidified aqueous supernatant suggested that HF-SLME functioned in a selective manner with high enrichment factors of the analytes enough for GC analysis[18].However, when free exudate of meat slurry with a sample/water ratio of 1:3 (g/mL) was directly subjected to GC analysis, only a small but deformed peak was presented for acetic acid against a sharp and symmetric peak for internal standard. The fact suggested trace amounts of VFAs present in meats. From obtained chromatograms, it is clear to see that all analytes including internal standard were eluted form the column within 6 min. If the HF-SLME was performed during the night as suggested previously[17], the total working time for the developed method is less than 1 h, including sample and f iber preparation and GC analysis.

2.2.2 Linearity, detection limits and quantif ication limits

With the present method, it took a short time to analyze meat samples, the retention times and detection limits were described in Table 1.

Table 1 Retention times, limits of detection and limits of quantif ication of f ive volatile fatty acids

The detection limits of VFAs between 0.03 μmol/L and 0.16 μmol/L, and limits of quantif ication varying from 0.09 to 0.50 μmol/L were achieved which were low enough to be able to detect the concentrations of VFAs in the meat samples.

Table 2 Linear regression equations with linear range and correlation coeff icient of f ive volatile fatty acids

The range of concentrations studied and coeff icients of regression for each VFA were presented in Table 2. Linearity was evaluated in terms of the correlation coeff icients of the regression equations of the calibration curves. The calculated calibration curves exhibited a good linearity for all VFAs,with the correlation coefficient (r) varying from 0.9261 to 0.9997. Concentration ranges were selected according to the concentration of VFAs in the meat, and enough to cover the possible concentration in various kinds of meat samples.

2.2.3 Recovery and reproducibility

A recovery of the 5 acids was employed to assess the extraction method in this work. The recovery of this work was determined with pork sample by spiking standard solutions containing 5 VFAs at 3 levels of concentration. The results summarized in Table 3 shown that spiked recoveries ranged from 71.0% to 123.1%, taking into account that the low concentration of VFAs, thus the relatively wide range of recoveries were acceptable.

Table 3 Recoveries of f ive volatile fatty acids in spiked pork samples

Table 4 Inter-day and intra-day assay RSDs for replicate determinations

To evaluate the hollow fiber technique for VFAs after the extraction, repeatability and reproducibility were tested for all the studied acids. The precisions presented as relative standard deviation on standard solution at level were 7.82%to 15.96% as shown in Table 4. The intra-assay relative standard deviation (RSD) and the inter-assay precision were measured at 10 runs a day and different days with a total of 15 runs, respectively. The intra-assay relative standard deviation in concentrations was low (7.82%-10.28%) to consider the method acceptable. Meanwhile, the inter-assay precision provided RSD values in the range 10.01%-15.96%.The method showed very good repeatability and reasonable reproducibility at a low concentrate of analytes. Meanwhile,it was suggested that it was best to analyze the sample as soon as possible.

2.3 Method application

2.3.1 VAFs content in various meat

The content of VAFs in pork, beef, mutton, chicken,duck meat and pigeon meat were determined by the developed method (Table 5). Among 5 target VAFs,acetic acid appeared to be the most abundant acid in meat (68.92 to 676.75 mg/kg), and several acids were present at lower concentrations: i-butyric acid (28.24-45.52 mg/kg), n-butyric acid (10.03-47.27 mg/kg), i-valeric acid(5.05-19.53 mg/kg). The total VFAs in meats of livestock(725.30-845.23 mg/kg) are much higher than that from poultry (192.82-282.39 mg/kg).

As shown, the total amounts of VFAs among pork,beef and mutton determined were generally similar, and the total VFAs content in poultry including chicken,duck and pigeon were up to a similar amount. It was significantly different (P<0.05) that the amount of acetic acid between the livestock and poultry, and which may be used to differentiate meat species of the livestock and poultry.The differences could be related to reasons such as metabolic mechanism, total amount of fat and breeding. Wood et al[19]reviewed the difference of fatty acid composition in pigs,sheep an cattle was due to the total amount of fat. Results presented by Demirel et al[20]showed that breed type was one of the main factors affecting the fatty acid compostion of meat. There was no significant difference (P>0.05) of propionic acid among the poultry, while propionic acid in beef was signif icantly higher than pork and mutton.

2.3.2 Effects of freshness on the content of VFAs in pork

The content TVB-N and pH value, as the important reference index, are used to evaluate pork freshness. TVB-N compounds contain mainly ammonia, trimethylamine anddimethylamine, and the levels of TVB-N compounds increase with spoilage by either bacterial or enzymic degradation.TVB-N values were reported to increase curvilinearly or linearly with time, and a level of 25 mg/kg muscle TVB-N/100 g has been considered the upper limit above which pork products are considered spoiled and unfit for human consumption. Meanwhile, the increasing pH was due to the protein degradation by microorganism and amines were produced.

Table 5 Volatile fatty acid contents in meat samples

Fig. 2 Correlations of total VFAs content with total volatile basic nitrogen (A) and pH (B) in pork

The plots of pH and TVB-N values against VFAs content of pork with different degree of freshness were presented in Fig. 2. Raw meat can have some level of microbial contamination present, which leads to the dominance of these spoilage microorganisms such as Brochothrix thermosphacta, Pseudomonas spp., and lactic acid bacteria[21]. Microbial spoilage responses to many factors including temperature, curing ingredients and environmental conditions. Storage of fresh meat may have pathogens such as Listeria monocytogenes, Salmonella spp., and E. coli O157:H7[22]. When pork stored under room environment from 5 h to 42 h, the total contents of VFAs decreased, while the contents of i-butyric acid and i-valeric acid increased. Brochothrix thermospphacta produces acetic acid, i-butyric acid and i-valeric acid as major end-products.The possibility that i-butyric and i-valeric acids were being formed from valine and leucine respectively. The acetic acid was lower with prolonged storage because of the higher pH(6.1 to 6.7) of meat, which was in agreement with previous report[23]. The changes of trace amount fatty acids may be due to that lactic acid bacteria degraded amino acids to produce VFAs[24].

A relationship between the contents of total VFAs and TVB-N was examined for the pork samples stored for different hours. total content of VFAs decreased from the beginning, which indicated that after 42 h of storage, the pork was not suitable for human consumption since it reached a value of 26.14 mg of TVB-N/100 g of muscle, which is above the maximum allowed. Meanwhile, the total content of VFAs was constant at 368.48 mg/kg. A relatively highly signif icant linear regression was obtained (y=-0.076x+54.09) with a regression coeff icient of 0.7890 between VFAs and TVB-N.The linear regression between VFAs and pH was fitted as:y=-0.0053x+9.18 (r=0.7592). Biophysical methods of assessment can measure meat component properties by using relative correlations between biophysical measurements and meat component properties. There was a negative linear correlation between content of VFAs and TVB-N, as well as the correlation between content of VFAs and pH. These indicated that there was a negative linear correlation between VFAs and meat freshness, and there was a possibility to determine VFAs contents as one aspect of measurement of meat freshness. These results suggested that the extraction of the VFAs using HF-SLME method combined with GC can be applicable to the assessment of meat freshness.

3 Conclusions

Determination of VFAs using HF-SLME method appears to be suitable for the analysis of trace level of VFAs which can be a potential indication reflecting the meat freshness. To our knowledge, the relationship between VFAs and meat freshness are rarely reported before and it shows the advantages of the developed method, which includes less organic solvent and time-consuming, inexpensive equipment,and simple operation. The present method was proved to be applicable to the assessment of meat freshness.

[1] GALDIKAS A, MIRONAS A, SENULIEN D, et al. Response time based output of metal oxide gas sensors applied to evaluation of meat freshness with neural signal analysis[J]. Sensors and Actuators B,2000, 69(3): 258-265.

[2] KANEKI N, MIURA T, SHIMADA K, et al. Measurement of pork freshness using potentiometric sensor[J]. Talanta, 2004, 62(1):217-221.

[3] NOH D H, CHUNG S H, CHOI S J, et al. A preliminary study on the development of an easy method for beef freshness using a cyclic voltammetric system[J]. Food Control, 2011, 22(1): 133-136.

[4] HERNÁNDEZ-CÁZARES A S, ARISTOY M C, TOLDRÁ F.Hypoxanthine-based enzymatic sensor for determination of pork meat freshness[J]. Food Chemistry, 2010, 123(3): 949-954.

[5] YANG Mingyang, CHOONG Y M. A rapid gas chromatographic method for direct determination of short-chain (C2–C12) volatile organic acids in foods[J]. Food Chemistry, 2011, 75(1): 101-108.

[6] CALKINS C R, HODGEN J M. A fresh look at meat f lavor[J]. Meat Science, 2007, 77(1): 63-80.

[7] RANAU R, STEINHART H. Identif ication and evaluation of volatile odor-active pollutants from different odor emission sources in the food industry[J]. European Food Research and Technology, 2005, 220(2):226-231.

[8] HORÁK T, ULÍK J, JURKOVÁ M, et al. Determination of free medium-chain fatty acids in beer by stir bar sorptive extraction[J].Journal of Chromatography A, 2008, 1196-1197: 96-99.

[9] LI Yun, XIONG Yongqiang, LIANG Qiangyong, et al. Application of headspace single-drop microextraction coupled with gas chromatography for the determination of short-chain fatty acids in RuO4 oxidation products of asphaltenes[J]. Journal of Chromatography A, 2010, 1217(22): 3361-3566.

[10] NIVEN S J, BEAL J D, BROOKS P H. The simultaneous determination of short-chain fatty acid, monosaccharides and ethanol in fermented liquid pig diets[J]. Animal Feed Science and Technology,2004, 117(3/4): 339-345.

[11] SAGRISTÀ E, LARSSON E, EZODDIN M, et al. Determination of non-steroidal anti-inflammatory drugs in sewage sludge by direct hollow f iber supported liquid membrane extraction and liquid chromatography-mass spectrometry[J]. Journal of Chromatography A,2010, 1217(40): 6153-6158.

[12] ZHANG Zhe, TONG Jin, CHEN Donghui, et al. Electronic nose with an air sensor matrix for detecting beef freshness[J]. Journal of Bionic Engineering, 2008, 5(1): 67-73.

[13] JAY J M, VILAI J P, HUGHES M E. Profile and activity of the bacterial biota of ground beef held from freshness to spoilage at 5-7 ℃[J]. International Journal of Food Microbiology, 2003, 81(2):105-111.

[14] CAI Jianrong, CHEN Quansheng, WAN Xinmin, et al. Determination of total volatile basic nitrogen (TVB-N) content and Warner-Bratzler shear force (WBSF) in pork using Fourier transform near infrared (FTNIR) spectroscopy[J]. Food Chemistry, 2011, 126(3): 1354-1360.

[15] LIU J F, TORÄNG L, MAYER P, et al. Passive extraction and clean-up of phenoxy acid herbicides in samples from a groundwater plume using hollow f iber supported liquid membranes[J]. Journal of Chromatography A, 2007, 1160(1/2): 56-63.

[16] CRUWYS J A, DINSDALE R M, HAWKES F R, et al. Development of a static headspace gas chromatographic procedure for the routine analysis of volatile fatty acids in wastewaters[J]. Journal of Chromatography A, 2002, 945(1/2): 195-209.

[17] ZHAO Guohua, LIU Jinfu, NYMAN M, JÖNSSON J Å. Determination of short-chain fatty acids in serum by hollow fiber supported liquid membrane extraction coupled with gas chromatography[J]. Journal of Chromatography B, 2007, 846(1/2): 202-208.

[18] JÖNSSON J Å, MATHIASSON L. Liquid membrane extraction in analytical sample preparation[J]. Trends in Analytical Chemistry,1999, 18(5): 325-334.

[19] WOOD J D, ENSER M, FISHER A V, et al. Fat deposition, fatty acid composition and meat quality: a review[J]. Meat Science, 2008, 78(4):342-358.

[20] DEMIREL G, OZPINAR H, NAZLI B, et al. Fatty acids of lamb meat from two breeds fed different forage: concentrate ratio[J]. Meat Science, 2006, 72(2): 229-235.

[21] MCDONALD K, SUN D W. Predictive food microbiology for the meat industry: a review[J]. International Journal of Food Microbiology,1999, 52(1/2): 1-27.

[22] PARK S, MARSH K S, DAWSON P. Application of chitosanincorporated LDPE film to sliced fresh red meats for shelf life extension[J]. Meat Science, 2010, 85(3): 493-499.

[23] DAINTY R H, HIBBARD C M. Aerobic metabolism of brochothrix thermosphacta growing on meat surfaces and in laboratory media[J].Journal of Applied Bacteriology, 1980, 48(3): 387-396.

[24] KOUTSOUMANIS K P, STAMATIOU A P, DROSINOS E H, et al. Control of spoilage microorganisms in minced pork by a selfdeveloped modif ied atmosphere induced by the respiratory activity of meat microf lora[J]. Food Microbiology, 2008, 25(7): 915-921.


登录APP查看全文

猜你喜欢

重庆
重庆客APP
新基建,重庆该怎么干?
平凡英雄 感动重庆
重庆人为什么爱吃花
数说:重庆70年“账本”展示
“逗乐坊”:徜徉相声里的重庆味
视觉重庆
在这里看重庆
路过重庆
TWO DAYS IN CHONGQING 重庆两日