利用万能工具显微镜校准倒角触摸规的原理和实例
2023-07-13覃业钦周祖旭池世鹏
覃业钦 周祖旭 池世鹏



摘 要:倒角触摸规是用来检测工件光孔倒角的一类检具,检测工件光孔倒角前需要先对倒角触摸规进行校准,以便保证检测的准确性。传统校准倒角触摸规的方法是使用一套特定工装,外加两根辅助测量棒,以及一个千分表组合,即可实现校准。本文从另一个视角,介绍利用万能工具显微镜校准倒角触摸规,此方法首先通过几何知识和代数知识推导,得出高度h的表达式,从而确定L的起点和止点,利用万能工具显微镜测出L的长度,再代入倒角触摸规校准尺寸Φ的表达式,便可以得到倒角触摸规校准尺寸Φ的实际值。
关键词:倒角触摸规 万能工具显微镜 校准
Principles and Examples of Calibrating Chamfered Touch Gauges Using a Universal Tool Microscope
Qin Yeqin,Zhou Zuxu,Chi Shipeng
Abstract:Chamfered touch gauge is a kind of inspection gauge used to detect the chamfer of the workpiece smooth hole, and the chamfer touch gauge needs to be calibrated before detecting the chamfer of the workpiece smooth hole to ensure the accuracy of the detection. The traditional method of calibrating a chamfered touch gauge is to use a specific fixture, plus two auxiliary measuring rods, and a dial indicator. This paper introduces the use of universal tool microscope to calibrate the chamfered touch gauge from another perspective. The method first derives the expression of height h through geometric knowledge and algebraic knowledge, so as to determine the starting and ending point of L, uses the universal tool microscope to measure the length of L, and then substitutes the expression of the chamfer touch gauge calibration size Φ to obtain the actual value of the chamfered touch gauge calibration size Φ.
Key words:chamfer touch gauge, universal tool microscope, calibration
1 校准倒角触摸规的传统方法
倒角触摸规是用来检测工件光孔倒角的一类检具,为了保证检测的准确性,必须先保证倒角触摸规是符合设计尺寸要求的,这就需要定期去校准倒角触摸规。倒角觸摸规主要校准尺寸是两根辅助测量棒间的距离Ф(如图1),传统方法是使用一套倒角触摸规校准特定工装(如图2),外加两根辅助测量棒,以及一个千分表组合。把倒角触摸规的测量销拆卸下来,垂直放置在工装上,工装两平面紧贴两个辅助测量棒,两个辅助测量棒紧贴测量销倒角(如图3),便可以在千分表上读出尺寸Ф的实际值。
2 传统方法的局限性
使用特定工装校准倒角触摸规,工装精度不高,使用辅助测量棒贴合测量存在间隙的可能,会造成误差,且全程需要手工操作,人工误差较大,同时,辅助测量棒的制造误差也会累积到测量误差里面,从而导致测量结果不是那么的可靠。……