主热传输泵轴封失效诊断与响应
2021-07-23张晓晖秦川王宁宁
张晓晖 秦川 王宁宁

张晓晖 秦川 王宁宁
中核核电运行管理有限公司 浙江 嘉兴 314300
摘要:主热传输泵运行在主热传输系统高温、高压的环境下,主热传输泵轴封性能的好坏将直接影响主热传输泵是否可以维持运行,甚至可能导致发生重水泄漏的严重后果。本论文从主热传输泵轴封的结构特点出发,基于实际事故工况下的参数变化和系统设备响应,分析发生的主热传输泵机械密封失效故障工况的机理和现象、以及故障可能导致的后果,并给出响应方案。
关键词 主泵轴封;失效;诊断;响应
Failure Diagnosis and Response of Main Heat Transfer Pump Shaft Seal
ZHANG Xiaohui QIN Chuan WANG Ningning
(CNNC Nuclear Power Operations Management Co.Ltd, Jiaxing, Zhejiang Province, 314300 China )
Abstract: The main heat transfer pump operates in the high temperature and high pressure environment of the main heat transfer system. The performance of the shaft seal of the main heat transfer pump will directly affect whether the main heat transfer pump can maintain its operation, and may even lead to serious consequences of heavy water leakage. Based on the structural characteristics of the shaft seal of the main heat transfer pump, this paper analyzes the mechanism and phenomenon of the failure of the mechanical seal of the main heat transfer pump, and the possible consequences of the failure, and gives the response scheme.
Key Words: Main pump shaft seal; Failure; Diagnosis; Response
概述
秦山第三核電厂是从加拿大引进的CANDU-6型核电厂,是采用重水作为慢化剂和冷却剂的天然铀反应堆。正常运行时,依靠主热传输泵运转所提供的驱动压头来维持冷却剂的循环流量,从而为堆芯燃料提供冷却,同时将燃料裂变产生的热能带到蒸汽发生器并传给二次侧的轻水产生蒸汽,驱动汽轮发电机组发电[1]。主热传输泵(以下简称主泵)是单级单吸双排立式离心泵,由一台额定功率为6.7MWe的鼠笼感应电机驱动,设计流量2227.59 l/s,扬程215 m,转速1500 rpm,工作压力9.5-11MPa,工作温度260℃,泵体内仅有一组水润滑导轴承。密封形式为三级机械密封带后备密封,型号 Sulzer Bingham RV850,每一道机械密封包含一个动环和一个静环,每两个动静环部件之间会相互摩擦发热,需要流量恒定的冷却水连续对其进行冷却[2]。
主泵轴封主要结构介绍
在主泵大轴上,由下到上有泵主叶轮、轴套、轴承、辅助叶轮、轴封组件等,然后通过联轴器与主泵电机轴相连接。……