稳流器与旁路对火电厂烟气脱硫效率的研究分析

2021-07-15马翔金

科技资讯 2021年9期

马翔金

摘  要:该文提出一款可应用于湿法烟气脱硫工艺的双旁路直流旋风脱硫除尘器,对其进行了实验测试,并对热态烟气脱硫方案脱硫效果进行了研究与分析。研究表明:采用组合式的喷头开启方式能够很大程度上增加系统的脱硫效率,且配置双旁路+稳流器式旋转分离器不仅具有更好的稳定性,而且能够在入口流速较小的情况下达到最大脱硫效率,降低了整个装置的能耗,脱硫效率可达到90%以上。

关键词:烟气脱硫  双旁路直流旋风  NaOH溶液  脱硫效率

中图分类号:X773                           文献标识码:A文章编号:1672-3791(2021)03(c)-0053-03

Research and Analysis of Flow Stabilizer and Bypass on the Efficiency of Flue Gas Desulfurization

in Thermal Power Plants

MA Xiangjin

(Inner Mongolia Guohua Zhungeer Power Generation Co., Ltd., Ordos, Inner Mongolia Autonomous Region, 017000  China)

Abstract: A double bypass DC cyclone desulfurizer that can be applied to the wet flue gas desulfurization process was proposed and tested, the experimental process of the hot flue gas desulfurization program is given, the desulfurization effect of the hot flue gas desulfurization program is studied and analyzed. Studies have shown that the combined nozzle opening method can greatly increase the desulfurization efficiency of the system. The configuration of double bypass + stabilizer type rotary separator not only has better stability, but also can achieve the maximum desulfurization efficiency under the condition of a small inlet flow rate, the energy consumption of the entire device is reduced, and the desulfurization efficiency can reach 90% the above.

Key Words: Flue gas desulfurization; Double bypass direct current cyclone; NaOH solution; Desulfurization efficiency

在我國,火力发电厂是提供电能的主要来源,同时也是煤炭年均消耗量最多的工业之一。考虑到经济的快速发展,火力发电仍将以300亿W的年装机容量继续快速发展。这也就意味着煤炭的用量也将会逐年递增,因此,对燃煤烟气进行脱硫处理等问题急需得到解决。

如何在保证工业和经济健康发展的前提下,做到零污染排放是国家和企业必须面临的重要问题。在2014年9月,国家能源局、环境保护部和国家发改委对火力电厂燃煤释放烟气制定相关标准。该文以位于内蒙古鄂尔多斯市准格尔旗薛家湾镇国华电厂原有烟气脱硫装置作为研究对象,按照其尾气处理工艺流程装置搭建实验脱硫除尘装置系统,针对火力发电厂原有尾气脱硫装置存在的脱硫效率低和工艺不稳定等问题,提出改进措施,重点考察了脱硫剂种类、脱硫方法、分离器的脱硫装置等因素对脱硫效率的影响,同时也探究了旁路和稳流器对直流旋风分离器性能的影响。……