三种类型压水堆核电厂化容系统对比分析
2021-03-10张博
张博

摘要:本文选取主流的CPR1000、WWER-1000和AP1000三类百万千瓦级压水堆核电厂的化容系统,对其在执行容积、化学和反应性方面的控制模式进行分类说明,寻找各自在化学添加、设备布置、可靠性设计等方面的特点。通过比较分析,展现出各类化容系统的优势和不足之处,突出展现AP1000化容系统基于非能动和“做减法”的设计理念。最后,借鉴其他化容系统,给出了CVS系统的改进意见。
关键词:核电厂 AP1000 化容系统 化学控制 容积控制
Abstract: In this paper, it selects three types of chemical and volume control systems on mainstream PWR nuclear power plants including CPR1000, WWER-1000 and AP1000. Firstly it describes the control modes of these systems in the volume, chemical and reactivity controls. Then, it finds out their own characteristics in chemical adding, equipment layout and reliability design. Through comparative analysis, it shows the advantages and disadvantages of various chemical and volume systems, and highlights the design concept of AP1000 chemical and volume system based on passive and "subtraction". Finally, based on other chemical and volume systems, the improvement suggestions of CVS system are given.
Key Words: Nuclear power plant; AP1000; Chemical and volume control system; Chemical control; Volume control
现阶段我国主流百万千瓦级压水堆核电涵盖了CPR1000、WWER-1000和AP1000等堆型。各堆型在系统设计上相似性和差异性并存。化学和容积控制系统,作为核电厂一回路重要辅助系统,就是这方面的典型。本文选取CPR1000的RCV系统、WWER-1000的KBA系统、AP1000的CVS系统进行介绍,阐述共性,梳理特点,为提高核电厂化容系统运行水平提供参考。
1.系统描述和特点
1.1 RCV系统
RCV系统由下泄回路、净化回路、上充回路、轴封水及过剩下泄五部分组成。还有一条低压下泄管线和一条除硼管线。执行化学、容积和反应性控制,以及主泵密封水注入、辅助喷淋、过剩下泄、一回路充排水和水压试验、低压下泄和净化等功能[1]。系统特点:(1)设有容积控制箱作为一回路容积缓冲。超出缓冲能力时,由反应堆硼和水补给系统供水,通过上充泵给一回路补水,并通过连接管线将水排向硼回收系统,稳定稳压器水位在程控水位。(2)过剩下泄管线在正常下泄流道不能运行或主系统建立汽腔需要增大主系统排水的情况下,提供备用下泄流道。……