改良设计后腹膜透析连接管路系统在腹膜透析防错位接触污染中的应用效果
2019-01-08卢红华肖丽萍梁洁娴陈萍丽刘德慧
卢红华 肖丽萍 梁洁娴 陈萍丽 刘德慧



[摘要]目的 改良設计后腹膜透析连接管路系统在腹膜透析防错位接触污染中的应用效果,解决腹膜透析患者及家属换液时碰触污染问题。方法 回顾性分析2017年5月~2018年10月我院收治的102例腹膜透析管术患者的临床资料,按照连接管路系统不同分为对照组(51例)和观察组(51例)。观察组采用改良设计后腹膜透析连接管路系统,对照组采用原连接管路系统。比较两组的并发症发生率、实用性及满意度。结果 观察组并发症总发生率和连接管路问题发生率显著低于对照组,差异有统计学意义(P<0.05);观察组护士和患者的总满意度显著高于对照组,差异有统计学意义(P<0.05)。结论 改良的腹膜透析管路系统使腹膜透析患者能准确连接各管路,减少无菌端口污染,预防腹膜透析相关性腹膜炎、管路问题和护理不良事件的发生,提高连接管路系统实用性及患者和护士的满意度,值得临床推广应用。
[关键词]腹膜透析;接触污染;连接管路系统;改良设计;护理
[中图分类号] R473 [文献标识码] A [文章编号] 1674-4721(2019)11(b)-0239-04
Application effect of improved design of retroperitoneal dialysis connection pipeline system in preventing contamination caused by dislocation and contact during peritoneal dialysis
LU Hong-hua XIAO Li-ping LIANG Jie-xian CHEN Ping-li LIU De-hui
Ganzhou People′s Hospital, Jiangxi Province, Ganzhou 341000, China
[Abstract] Objective Application effect of improved design of peritoned dialysis connection pipeline system in preventing dislocation contact contamination of peritoneal dialysis to solve the problem of contact contamination of peritoneal dialysis patients and their families during fluid exchange. Methods Clinical data of 102 patients with peritoneal dialysis catheterization admitted to our hospital from May 2017 to October 2018 were retrospectively analyzed. The patients were divided into the control group (51 cases) and the observation group (51 cases) according to the different connection pipeline systems. The observation group used the modified design of retroperitoneal dialysis connection pipeline system, while the control group used the original connection pipeline system. Complications, utility, and satisfaction were compared between the two groups. Results The total incidence of complications and the incidence of connecting pipe problems in the observation group were significantly lower than those in the control group, and the differences were statistically significant (P<0.05), and the total satisfaction of nurses and patients in the observation group was significantly higher than that in the control group, and the differences were statistically significant (P<0.05). Conclusion The improved peritoneal dialysis pipeline system enables peritoneal dialysis patients to connect each pipeline accurately and correctly, reduce the contamination of sterile ports, prevent peritonitis, pipeline problems and nursing adverse events related to peritoneal dialysis, and improve the practicability of the connecting pipeline system and the satisfaction of patients and nurses. It is worthy of clinical application.
[Key words] Peritoneal dialysis; Contact pollution; Connecting pipeline system; Improved design; Nursing
腹膜透析(peritoneal dialysis,PD)是急性肾损伤和慢性肾衰竭的主要治疗手段[1-2]。其原理利用腹膜的半透膜特性,通过腹透连接管路系统规律、定时地向腹腔内注入透析液,高浓度的透析液产生渗透作用,以清除体内毒素和多余水分,促进电解质平衡来发挥类似肾脏的排泄作用[3-5]。该治疗手段能保护残余肾功能、透析效率高、花费低、操作简便,选择PD治疗的患者较多。但PD的无菌操作要求高,需熟练掌握PD的操作过程并严格执行无菌操作,否则易引起PD相关性感染,引发PD严重并发症,导致PD失败甚至死亡[6-7]。传统的PD换液连接管路系统中的三个无菌端口连接时容易出现连接错位导致外接短管口接触性污染,影响透析效果。本研究对腹膜透析连接管路系统进行了改良设计以减少无菌端口污染,经过6个月的临床实践,效果良好,现报道如下。……