[摘要] 目的 建立测定脂溶性维生素注射液中维生素D2、维生素E的高效液相色谱(HPIC)分析方法。 方法 应用高效液相色谱法。维生素D2采用Kromasil 100-5sil(250mm×4.6mm)色谱柱:以正已烷:异丙醇(97.5:2.5)为流动相:流速为1ml/min):检测波长为265nm:柱温室温:紫外测器。维生素E采用Kromasil 100-5sil(250mm×4.6mm)色谱柱:以正已烷-异丙醇(99.5∶0.5)为流动相:流速为1mL/min:检测波长为298nm:柱温室温:紫外检测器。结果 维生素D2和维生素E分别在0.26~2.08?g/mL和0.64~3.20mg/mL范围内与峰面积线性关系良好。维生素D2和维生素E的平均回收率分别为98.90%、100.2%、RSD分别为1.2%、1.1%。结论 本方法准确、快速、重现性好。

[关键词] 维生素D2;维生素E;高效液相色谱法;含量测定

[中图分类号] R927.2 [文献标识码] A [文章编号] 2095-0616(2017)15-46-05

[Abstract ] Objective To develop the HPLC method for determination of vitamin D2,vitamin E content in the Fat-soluble vitamin injection. Methods High performance liquid chromatography(HPLC) was used.Kromasil 100-5sil(250mm×4.6mm) chromatographic column was used to determine vitamin D2,n-hexane: isopropanol(97.5:2.5) was as mobile phase,the flow rate was 1ml/min,wavelength was 265nm,under the condition of room temperature,and UV-detector were used.Kromasil 100-5sil(250mm×4.6mm) chromatographic column was used to determine vitamin E:n-hexane:isopropanol(99.5∶0.5) was as mobile phase,the flow rate was 1ml/min,the wavelength was 298nm,under the condition of room temperature,and UV-detector were used. Results There was a good linear relationship between the 0.26-2.08?g/mL range and peak area for vitamin D2,while the 0.64-320?g/mL range for vitamin E.The average recovery rate of vitamin D2 and vitamin E were 98.90% and 100.2%.RSD of vitamin D2 and vitamin E were 1.2% and 1.1%. Conclusion The method is accurate,rapid and reproducible.

[Key words] Vitamin D2;Vitamin E;Chromatography(HPLC);Determination

脂溶性維生素注射液为含有维生素A、维生素D2、维生素E、维生素K1和注射用大豆油,卵磷脂等的灭菌乳剂,属维生素类药。用于脂溶性维生素缺乏的预防和治疗。其中维生素D又称钙化醇,维生素D种类很多。以维生素D2(麦角钙化醇)和维生素D3(胆钙化醇)较为重要。维生素D的主要生理功能是:调节钙、磷代谢、促进钙、磷吸收。缺乏时,儿童和哺乳期妇女更为明显。维生素E[1-3]又名生育粉,维生素E有很强的抗氧化作用。同时具有提高维生素A功能的作用;维生素E缺乏将导致红血球被破坏。肌肉的变性。贫血症,生殖机能障碍等病变[4-6],由于维生素E结构复杂,异构体多,准确分析测定较困难,近年来许多科学家致力于其分析的研究,开发了很多实用高效的检测方法,既有物理和化学方法,也有仪器分析方法 ,既有维生素E的总含量检测,也有异构体含量检测等。……

登录APP查看全文