APP下载

X射线荧光光谱法测定氧化物多组分含量的探讨

2025-08-06刘伟明

中国标准化 2025年13期
关键词:光谱法氧化物X射线

Discussion on the Determination of Content of Multi-component Oxides by X-ray Fluorescence Spectroscopy

LIU Weiming (Yantai StandardMetrology Inspectionamp; Test Center)

Abstract:This paperuses the X-ray fluorescence spectroscopy to establish analytical working curves for the six componentsofoxides,andverifiestheaccuracyand precisionanalysis.Theexperimentalresultsshowthattheaccuracy and precision of using X-ray fluorescence spectroscopy to analyze the content of multi-component oxides meet the requirementsofanalyticalwork,andtheoperationissimpleandeasywithhighanalysisefciency.Itcanacuratelyand reliably conduct qualitative and quantitative analysis of the multi-component oxides.

Keywords:X-ray fluorescence spectrometry;oxide;multiple components;content

0 引言

强度,可获得各元素的含量信息,此方法为快速、准确分析各种氧化物多组分含量提供了可能[-2]。本文拟通过使用波长色散X射线荧光光谱仪,基于熔融制样法建立氧化物多组分的分析工作曲线,实现使用一组工作曲线完成对氧化物多组分含量的检测。

矿石、陶瓷、水泥等氧化物多组分含量的检测,常用的化学分析法操作烦琐并且产生废酸碱及重金属污染,且不能满足大批量样品的快速分析要求。X射线荧光光谱法根据各元素的特征X射线的

1 试验部分

1.1仪器设备和试验条件

(1)仪器设备:PW4400型波长色散X射线荧光光谱仪(帕纳科),熔样炉。

(2)选定氧化物的测量条件见表1。根据所使用仪器的状态、试样的种类、分析元素、共存元素及其含量变化范围,选择合适的测量条件。

1)首先选择试验电压电流:本试验通过改变光管电压和电流,调节待测元素X射线的荧光强度,选择适合各元素检测的电压和电流,以获得可满足氧化物元素检测需要的荧光强度。

2)选择分析谱线:选择分析谱线的原则是干扰谱线少、强度适当、背景稳定。根据上述选择分析谱线的原则分别选用L β1,Kα 、Lα谱线。

3)选择探测器:PW4400型X射线荧光光谱仪配置流气检测器(Flow)和闪烁检测器(Scint.),除了Pb元素选择闪烁检测器(Scint.),其他5个元素选择流气检测器(Flow)。

4)分析元素的测量时间取决于待测元素的含量及所要达到的分析精密度,为满足分析需要,选择4\~28s[3-6]

1.2试剂

(1)脱模剂:碘化铵( NH4I 或溴化铵( ΔNH4Br) 。

(2)熔剂:无水四硼酸锂( [i2B4O7 ),优级纯,在 700∘C 灼烧 4h ,贮存于干燥器中。……

登录APP查看全文

猜你喜欢

光谱法氧化物X射线
CT:洞察身体的“透视眼”
分子内原子的“协同舞蹈”现象成功捕获
臭氧氧化法降解印染废水研究现状
骨质疏松症诊断的“金标准”
三菌联合型功能微生物菌剂对土壤和稻米砷的阻控研究
T/CBWA0028一2024《燃煤性能指标快速检验方法激光诱导击穿光谱法》解读
X射线的神奇故事
郑州荥阳市周边土壤重金属含量垂向变化与结合态特征研究
食品中微量成分的检测技术及控制策略分析
“能源容器”的密码