APP下载

三种机用镍钛器械预备弯曲根管成形能力的比较研究

2025-06-13贺莹刘鹏飞王培娜褚晓月郭静

中国美容医学 2025年6期

[摘要]目的:比较Reciproc Blue R25、S3小旋风(BS+B套装)和ORODEKA plex2.0 (06锥度)三种机用镍钛器械预备弯曲根管的根管偏移和中心定位能力。方法:选取30颗模拟离体牙的弯曲树脂根管,随机分为三组,每组10颗。分别用Reciproc Blue R25、S3小旋风和ORODEKA plex2.0三种不同的机用镍钛器械采用冠向下法预备根管,使用相机拍摄根管预备前后的根管图像,借助制图软件进行预备前后对比收集数据,评价预备后的根管偏移和中心定位能力。结果:Reciproc Blue R25(组1)的预备时间最短,显著小于S3小旋风(组2)和ORODEKA plex2.0(组3)(P<0.05);在根尖区,Reciproc Blue R25(组1)的根尖偏移大于S3小旋风(组2)和ORODEKA plex2.0(组3)(P<0.05);根管弯曲段ORODEKA plex2(组3)根管中心定位能力优于其余两组(P<0.05);弯曲上段,三组间差异无统计学意义(P>0.05)。结论:三种镍钛器械均能维持根管原始形态,Reciproc Blue R25可有效、快速地预备根管;与Reciproc Blue R25相比,S3小旋风和ORODEKA plex2.0具有更好的根管成形能力,更适合弯曲根管的预备。

[关键词]根管治疗;镍钛器械;弯曲根管;根管偏移;中心定位能力;成形能力

[中图分类号]R783.1" " [文献标志码]A" " [文章编号]1008-6455(2025)06-0149-04

Comparative Evaluation Study of Shaping Ability of Three Nickel-titanium Instruments in Curved Root Canals

HE Ying1, LIU Pengfei1, WANG Peina1, CHU Xiaoyue2, GUO Jing1

( 1.Department of Stomatology, Xi'an No.3 Hospital, the Affiliated Hospital of Northwest University, Xi'an 710018, Shaanxi, China; 2.Blood Group Reference Laboratory, Shaanxi Blood Center, Xi'an 710061, Shaanxi , China )

Abstract: Objective" The purpose of this study is to compare the shaping ability of Reciproc Blue R25、Sani BS+ and ORODEKA plex2.0 Ni-Ti instruments in curved root canals. Methodsnbsp; A total of thirty simulated resin blocks were divided randomly into three groups(n=10),preparing by the Reciproc Blue R25(Group 1),Sani BS+(Group 2) and ORODEKA plex2.0(Group 3),using crown-down technique.The images taken before and after preparations were captured using a precise camera and superimposed by Adobe Photoshop.Transportation incidence and centering ability were accessed. Results" Group1 demonstrated the least preparation time(P<0.05). In the apical area,group1 presented a higher transportation incidence than the others(P<0.05). Group3 showed a better centering ability than the others at the curved section(P<0.05). There was no significant difference among the three groups at the coranal curvature part(P>0.05). Conclusion" All the instruments maintained the original root curvature.No instrument separation was seen during preparation.Reciproc Blue R25(Group1) displayed the most efficient instrument.Sani BS+(Group 2) and ORODEKA plex2.0(Group 3) possessed better centering ability,suitable for curved root canals.

Key words: root canal therapy; Nickel-titanium instrument; curved root canal; apical transportation; center positioning ability; shaping ability

根管预备是根管治疗的关键步骤,传统不锈钢器械预备弯曲根管时易产生根管台阶、根尖敞开甚至根尖偏移等并发症,降低根管治疗的效果[1-2]。因此,选择成形能力良好的锉有重要意义。本研究的目的是通过对模拟弯曲根管的树脂模块进行预备,比较常用镍钛器械单支锉Reciproc Blue R25和传统的全序列连续旋转运动的S3小旋风、ORODEKA plex 2.0三种镍钛器械预备弯曲根管的成形能力,为临床选择镍钛器械提供理论依据。

1" 材料和方法

1.1 实验分组:将30个弯曲角度为45°的单弯树脂模型(萨尼,成都)随机分为3组,每组10个,编号1~30。……