血液标本保存时间对各生化检测指标的影响分析
2021-12-13相瑞瑞
相瑞瑞
【摘 要】目的:探讨在同等温度条件下,不同保存时间对各项生化指标的影响。方法:选取2020年10月至2021年3月的50份以真空促凝采血管采集的血液标本为研究对象,标本离心,取血清均放置于-18℃~-22℃环境中保存,分别于即刻、保存1周、2周和1个月后对血清标本进行生化检测,记录并对比不同时段测定值。结果:血液标本放置7d、14d、30d,部分生化指标与即刻检测差异均有统计学意义;冷冻7d的血清标本中ALT、BUN及TBIL水平与即刻检测水平对比超出允许误差范围;冷冻14d的标本,ALT、TBIL、BUN水平超出允许误差范围;冷冻30d的标本,TP、ALT、BUN、UA、GLU、ALB、CR超出允许误差范围。结论:在-18℃~-22℃环境中保存的血清标本随着保存时间延长,其生化检测指标也发生不同程度改变。
【关键词】血液标本;保存时间;检验误差;生化指标
Analysis of the preservation time of blood specimens on the biochemical detection index
Xiang Ruirui
Yuncheng Airport Hospital, Shanxi Yuncheng 044000, China
【Abstract】Objective:To explore the influence of different preservation times on various biochemical indexes under the same temperature conditions.Methods:50 blood samples collected by vacuum-coagulation blood vessels were selected as the research object.Thesamples were centrifuged and stored in-18℃~-22℃ environment.They were tested immediately, 1 week, 2 week and 1 month, and recorded and compared at different periods.Results: The statistical differences between partial biochemical index of 7d,14d,30d, and immediate detection; ALT, BUN and TBIL levels in frozen 7d exceeded the allowable error range compared with the immediate detection level; 14 d specimens with ALT, TBIL, BUN level exceeded the allowable error range; and 30 d specimens with TP, ALT, BUN, UA, GLU, ALB, CR exceeded the allowable error range.Conclusion: The biochemical indexes of serum specimens preserved in-18℃~-22℃ environment were changed with the preservation time.
【Key?Words】Blood specimen; Preservation time; Test error; Biochemical indicators
血液标本的保存是医学检验分析前质控的重要部分,血液标本放置时间对部分生化指标可产生不同程度影响[1]。本研究通过比较同等保存条件下不同保存时间的血液标本,旨在探讨不同保存时间对血液常规检测生化指标的影响。
1 材料与方法
1.1 材料来源
选取2020年10月至2021年3月50份血液标本进行研究,其中,男27例,女23例。研究涉及仪器与试剂:奥林巴斯AU680全自动生化分析仪。ALT、GLU、AST、TP、TBIL、ALB、UA、CR、BUN试剂及质控血清均由北京九强生物提供。
1.2 方法
取50份用真空促凝采血管采集的血液标本,每份5ml,血液自然凝固30分钟后进行离心处理,检查标本无溶血、混浊后,即刻吸取血清置于全自动生化分析仪样品杯中,上机测试。每份标本再吸取3份血清,放于尖底带盖离心管中,在-18℃~-22℃冰箱中保存。……