傅立叶变换红外分光光度法测定氯化氢废气
2021-11-25张晶


【摘要】 阐述了傅立叶变换红外分光光度法测定氯化氢废气的基本原理,并介绍了该方法采样测定的具体操作过程与注意事项,希望对相关部门开展固定污染源废气中氯化氢的监测工作带来一定参考借鉴。
【关键词】 傅立叶变换红外分光光度法;氯化氢;监测
【DOI编码】 10.3969/j.issn.1674-4977.2021.06.022
Determination of Hydrogen Chloride Waste Gas by
FTIR Spectrophotometry
ZHANG Jing
(Shenyang Environmental Monitoring Centre,Shenyang 110015,China)
Abstract: The basic principles of the FTIR spectrophotometric method for the determination of hydrogen chloride waste gas were described,and the specific operation process and precautions of the method for sampling and determination were introduced. It is hoped that it will be a reference for the relevant departments to carry out the monitoring of hydrogen chloride in the fixed pollution source waste gas.
Key words: FTIR;hydrogen chloride;monitoring
傅立叶变换红外分光光度法作为一种测试氯化氢废气的成熟方法,在国际上已受到广泛认可并在实际工作中使用。国际标准化组织(ISO)、英国环保署(UK Environmental Agency)和美国环保署(EPA)均已制定了使用傅立叶变换红外分光光度法测定固定污染源废气中氯化氢的标准或规范。该方法可在现场直接测试废气中的氯化氢并显示测试结果,不需要样品运输,不需要实验室分析,从根本上避免了采样及样品运输过程中的氯离子污染。该方法与采取现场采样——实验室分析模式的氯化氢监测方法相比,具有快速、简便、高效、数据质量高的优势,是固定污染源废气中氯化氢监测的一个新选择。
1 测定原理
用波长连续变换的红外光照射氯化氢分子时,与氯化氢分子固有振动频率相同的特定波长的红外光被吸收,并在检测器上得到干涉图,经过计算机傅立叶变换形成红外光谱图,红外光谱图中会显示该频率的吸收峰,根据吸收峰的数目、位置、形状等可对被测样品中的氯化氢进行定性分析,根据吸收峰的峰高、峰面积可对被测样品中的氯化氢进行定量分析。
2 试剂与仪器
1)零气
纯度≥99.99%的氮氣。……