APP下载

主柴油发电机组大小机并车试验方法研究

2021-11-09夏冬梅李春明陈欢

广东造船 2021年5期

夏冬梅 李春明 陈欢

摘    要:4000kW新型海洋救助船配置了4台主柴油发电机,分别为2台2600kW的大机和2台450kW的小机,实现了功率比接近6倍的大小机并车试验,而且在后续的使用中能稳定的运行。本文介绍了本船的用电工况和两种常用的并车模式,并简要介绍了并车模式的选择、调速信号的选择、并车流程的制定,以及实船并车试验情况,可供同类型船舶参考。

关键词:柴油发电机;并车;恒频模式;下垂模式

中图分类号:U664.23                               文献标识码:A

Test Method of Big and Small Diesel Generators Paralleling

XIA Dongmei, LI Chunming, CHEN Huan

( CSSC Huangpu Wenchong Shipbuilding Co., Ltd., Guangzhou 510715 )

Abstract: The new 4 000 kW ocean rescue ship(later called the ship) is equipped with four main diesel generators, which are 2 large ones of 2 600 kW and 2 small ones of 450 kW respectively. A test of big and small diesel generators paralleling with a power ratio of nearly six times is completed, and it can run stably in the subsequent use. This paper introduces the electrical working condition of the ship, two commonly used modes of diesel generators paralleling, selection of the ship's paralleling mode, analysis and selection of speed control signal,formulation of paralleling process, situation of the actual paralleling test, which can be used for reference for the same type of ships.

Key words: Diesel generator; Generators paralleling; Isochronous mode; Speed droop mode

1     前言

根据船舶为适应不同工况下的负荷需要,柴油发电机组并车以结构合理、安全可靠、高效节能为主要目标,使产品的各项性能指标均达到较高水平。本船主柴油发电机组大小机功率比之大是罕见的,本研究对功率悬殊的柴油发电机组并车具有重要意义。

2     主要研究内容

2.1    电站的配置及电力使用工况

2.1.1电站的配置

本船配有4台主柴油发电机,分别为2台2600 kW的大机和2台450 kW的小机,其电力单线图,如图1所示。

2.1.2电力使用工况

技术规格书要求的电力使用工况如下:

(1)全速航行工况

使用两台2 600 kW发电机组向全船供电,当负荷率超过90%时,若海況良好,则起动单台450 kW发电机组,两大一小发电机组向电网供电:电站自动限制450 kW发电机组的负荷率在80 %;如遇恶劣海况,起动两台450 kW发电机组进行负载转移,将450 kW和2600 kW发电机进行分区供电,2 600 kW发电机组驱动主推进器,450 kW发电机组驱动机舱泵、风机等400 V负载,同时将400 V汇流排联络开关断开。

(2)救险、消防作业工况

根据实际负荷率使用两台2 600 kW发电机组。……