通用测试设备在机载设备维修中的应用
2021-07-22宋文瑰焦梅素周彦凯贡志波
宋文瑰 焦梅素 周彦凯 贡志波



摘 要:随着三代战机装备陆续进入二翻期,配套机载设备内部电路板出现损伤的情况呈现上升趋势。本文旨在通过X射线分析仪和红外成像仪等通用测试设备检测损伤电路板内部缺陷及修复后效果,并完成某机载惯导损伤电路板修复。
关键词:通用设备;损伤修复;机载设备
中图分类号:V267文献标识码:A文章编号:1003-5168(2021)08-0062-03
Application of the General Test Equipment in Airborne
Equipment Maintenance
SONG Wengui JIAO Meisu ZHOU Yankai GONG Zhibo
(Shijiazhuang Haishan Industrial Development Corporation,Shijiazhuang Hebei 050208)
Abstract: As the third generation fighter aeroplane has entered the second renovation period, the damage of the internal circuit board of the supporting airborne equipment is on the rise. This paper aimed to detect the internal defects of the damaged circuit board and the effect after repair by using general equipment such as X-ray analyzer and infrared imager, and complete the repair of damaged circuit board of an airborne inertial navigation system.
Keywords: general equipment;damage repair;airborne equipment
在人类发展进程中,测量、测试一直扮演着重要角色,工业生产以及科学技术的开拓创新都离不开测量、测试技术的应用[1]。测试也是保证工程质量的有力武器,它决定了一个工程最终成败与否,可以说,测试技术已经成为一个国家科技水平的重要标志。随着科学技术的不断发展,各学科领域都对测试技术提出了越来越高的要求,任何一个新的学科理论和现代装备,如果没有先进的测试技术和仪器支持,其研究、设计和实现都是不可能的[2]。而通用测试仪器和设备的发展直接体现了测试技术的发展水平。通用测试设备水平的提升,对军用飞机修理检测提供了有效支持[3]。某军用飞机配套X型惯导部件在使用过程中突发掉电故障,通过分解检查,发现该惯导部件母线板、电源板严重烧蚀。现实条件下,X型惯导部件已陆续退出主战装备,修复X型损伤惯导所需专用器材大都停产,欲恢复装备,只能开展攻关修复。
1 故障基本情况
1.1 故障发生时机
该套X型惯导部件在外场通电约20 min时,设备舱冒烟,仪器显示“故障”灯亮,故障确定为惯导部件内部短路导致。……