APP下载

客运邮轮码头联检大厅暖通空调设计

2021-03-28陈晓晖

河南科技 2021年34期
关键词:暖通空调

陈晓晖

摘 要:以福州港松下港区牛头湾作业区0#~2#泊位客运中心工程旅检客运大楼为实例,分析客运邮轮码头联检大厅的建筑特点,阐述该类空间暖通空调工程的设计思路与步骤,并简单总结暖通空调设计要点与技术措施。

关键词:客运邮轮码头;联检大厅;暖通空调

中图分类号:TU83 文献标识码:A 文章编号:1003-5168(2021)34-00-03

HVAC Design of  Joint Inspection Hall of Passenger Cruise Terminal

CHEN Xiaohui

(Fujian Communications Engineering Consulting Co., Ltd., Fuzhou Fujian 350000)

Abstract: This article takes the passenger insfection termine building of the 0#~2# berth passenger transportation center project in the niutouwan operation area of the Sougxia port area of Fuzhou Port as an example, to analyze the architectural characteristics of the joint inspection hall of passenger cruise terminal, expounds the design ideas and steps of this space of HVAC project, and briefly summarizes the HVAC design points and technical measures.

Keywords: passenger cruise terminal; joint inspection hall; HVAC

1 工程概况

作为福州港松下港区牛头湾作业区0#~2#泊位客运中心工程,旅检客运大楼地处福州市长乐区,为地上二层建筑,总建筑面积为13 883 m,建筑总高为20.30 m。它的主要功能区域为联检大厅,大厅共一层,顶部为钢结构拱形屋顶。根据空间特点,它又分为大空间区域(包括检测通道、候检区及行包区)和大厅内区附属用房(包括检测部门用房、后勤管理用房及设备用房等)。

通过分析建筑专业提资的条件图,联检大厅具有以下特点:①跨度达到130 m,净高最高处达19.5 m,净高最低处为8.5 m,属于典型的高大空间;②大厅上空为钢结构桁架,屋顶为拱形钢结构,外围护结构面积大;③附属用房整体位于大厅内区,属于“房中房”的格局,设闷顶屋面,无自然通风条件;④使用部门为海关、公安边防及出入境检验检疫等互不统属的单位。

2 进行暖通空调设计

2.1 确定通风空调室内外设计参数

①空调室外计算参数参照《民用建筑供暖通风与空气调节设计规范》(GB 50736—2012)[1]附录A,此处不做引述。

②室内空调设计计算参数如表1所示。

③通风排气计算参数。大厅设备用房按排除余热余湿计算通风量,卫生间换气频率为每小时10次[1]。……