电站锅炉内部检验常见缺陷分析
2020-12-08何彦波
何彦波



【摘 要】在大型火力发电机组中,锅炉是其重要设备,一旦因锅炉缺陷导致设备非正常停运或损坏,将造成不良后果。为确保发电机组的安全稳定运行,有必要加强电站锅炉的内部检验工作,及早发现并解决其存在的缺陷。论文结合相关文献资料与多年工作实践,就电站锅炉内部检验中常见的缺陷进行分析。
【Abstract】In large thermal power generating unit, the boiler is its important equipment. Once the equipment is abnormally shut down or damaged due to boiler defects, it will cause adverse consequences. In order to ensure the safe and stable operation of power generating unit, it is necessary to strengthen the internal inspection work of power station boiler, and find and solve its defects as soon as possible. Combined with relevant literature and years of work practice, this paper analyzes the common defects in internal inspection of power station boiler.
【关键词】电站锅炉;内部检验;缺陷
【Keywords】power station boiler; internal inspection; defects
【中图分类号】TM621.2 【文献标志码】A 【文章编号】1673-1069(2020)11-0188-03
1 引言
火力发电机组投运后,随着运行时间的增加,电站锅炉设计、制造、安装、运行存在的问题会逐渐显现。对锅炉进行内部检验是发现其缺陷的主要方式之一,熟悉锅炉内部检验中常见的缺陷才能有针对性地开展检验工作,以达到发现并消除缺陷的目的,从而确保发电机组安全稳定地运行。本文列举了一些内部检验中常见的主要缺陷并对其进行分析,为今后检验人员开展工作提供一些实践经验。
2 受热面
2.1 磨损
磨损是受热面泄露中很常见的一种形式,一般分为机械磨损、飞灰磨损和蒸汽吹损。检验时,应重点检查管排与管排之间、管与管卡之间,以及管与结构件等之间是否存在挤压碰磨现象,与炉墙附近管排磨损情况,受热面管屏是否存在节距不均、管子出列等问题。
①机械磨损。机械磨损一般由于定位卡块失效或夹持不牢造成管排与管排之间、管排与夹持管之间出现磨损。应从设计、制造、安装及检修等方面规避此类问题的发生。
②飞灰磨损。……