电缆故障预定位中局部放电测量技术的应用分析
2018-08-30龚秋成翟俊芳
龚秋成 翟俊芳
摘要: 近几年以来,我国的电力系统快速建设发展,在传统的电缆故障预定位中使用的技术已经无法满足当前的技术发展需求,在电缆故障中存在许多故障点无法击穿以及燃弧时间比较短,所以造成许多电缆故障点无法被有效定位。而局部放电测量技术作为一种比较有效的定位技术,其能够在电缆的绝缘状态下进行有效检测和定位分析。但是在不同电压等级下电缆设备,需要分别采用不同的局部放电测量技术,才能达到良好的测量定位效果。本文主要针对电缆故障预定位中几种常用的局部放电测量技术的应用进行了全面分析,并提出了相关结论。
Abstract: In recent years, with the rapid development of China's power system, the technology used in the traditional cable fault pre-positioning can no longer meet the current technological development needs, there are many failure points in the cable fault that cannot be broken down and the arcing time is short, so many cable fault points cannot be effectively located. The partial discharge measurement technology as a relatively effective positioning technology, which can effectively detect and locate the cable in the insulation state. However, in different voltage levels, cable devices need to adopt different partial discharge measurement techniques respectively to achieve good measurement and positioning results. This paper mainly analyzes the application of several commonly used partial discharge measurement techniques in cable fault pre-positioning, and puts forward relevant conclusions.
關键词: 电缆故障;定位;局部放电;测量
Key words: cable fault;positioning;partial discharge;measurement
中图分类号:TM247 文献标识码:A 文章编号:1006-4311(2018)20-0227-02
0 引言
目前,我国逐渐开始大量应用交联聚乙烯电缆线路,而且在以往电缆线路长期运行的过程中,其一直保持高负荷运转,很容易出现各种故障问题,如果出现电缆绝缘故障,在架空线路的电缆故障检测、定位时具有较大的难度,传统的电缆故障预定位方式已经无法满足当前的使用需求,在当前的电缆故障定位工作中,必须充分结合电缆绝缘电阻的大小来进行准确判断,然而按照断线、低阻以及高阻的要求分别采用不同的预定位方式。根据实践研究发现,针对故障点无法击穿以及燃弧时间较短等问题,需要合理应用局部放电测量技术来进行定位,才能使故障预定位更加准确,有效提高电缆故障的检修效率。……