某超高层结构在水平荷载作用下楼板应力分析
2018-08-30陈林
陈林
摘要: 对于超高层大板结构,楼板不仅要承受竖向荷载和传递水平荷载,且还要协调各抗侧力构件之间的变形。通过YJK软件,采用弹性板6单元进行楼板应力分析,水平荷载下产生的楼板应力与竖向荷载下的应力进行对比分析,可知水平荷载产生的面外弯矩和面内应力不可忽视,给出了应力分布云图和各工况应力对比图表。通过楼板承载力简化计算公式,计算楼板配筋并给出相应楼板构造措施,为以后的工程提供一定的参考。
Abstract: For super high-rise slab structures, the slab not only bears vertical loads and transmits horizontal loads, but also coordinates the deformation between the anti-lateral forces. Through YJK software, the stress analysis of the floor slab is performed using the elastic plate 6 units. The stress between the floor stress generated under horizontal load and the stress under vertical load is compared and analyzed. It can be seen that the out-of-plane bending moment and in-plane stress produced by the horizontal load cannot be ignored. The stress distribution cloud diagram and the stress comparison chart for each working condition are given. Through the floor slab bearing capacity to simplified calculation formula, the floor reinforcement is calculated and the corresponding floor structure measures are given, to provide a certain reference for future projects.
关键词: 弹性板6;面外弯矩; 面内应力; 对比分析
Key words: elastic plate 6;out-of-plane bending moment;in-plane stress;comparative analysis
中圖分类号:TU318 文献标识码:A 文章编号:1006-4311(2018)20-0151-02
1 工程概况
本工程位于深圳市南山区蛇口,为商业、住宅及办公为一体的综合体,该项目四层全埋地下室,一层半地下室,三层裙房及五栋超高层塔楼,总建筑面积约23.1万m2。本文取A栋塔楼楼板进行分析,本塔楼主要用途为办公和公寓,框架核心筒结构,地下4 层,地上43 层,嵌固端在全埋地下室顶板,高度为189.9m,主楼柱网尺寸为7.3m 及6.7m。由于本楼要满足多种建筑功能的需要,且楼层荷载大的特点,所以结构外框柱与钢筋混凝土核心筒之间在X方向(短向)仅有四条框架梁相连,其余位置外框柱与内筒之间采用200mm现浇混凝土板连接。此结构形式较为复杂,结构中楼板的作用更为重要。
2 楼板设计中所面临的问题
对于高层结构而言,楼板内除了有面内的轴向正应力与剪应力外,还有面外的弯曲正应力。而目前楼板设计大多还采用的常规计算软件,只考虑竖向荷载的作用,而水平荷载作用下的楼板面内应力与面外正应力并未考虑。……