地铁工程裸露钢筋锈蚀危害及防治
2018-05-02单经年
单经年
【摘 要】现今钢材能源在各类施工生产中起着不可替代的作用,支撑建筑物的结构。在钢筋使用中,一般施工环境都比较恶劣,气候情况或者存放不当等因素,都会影响到钢筋的质量,使钢筋表面发生锈蚀,而一旦锈蚀严重必定影响后续工程结构整体的质量及安全,同时结构耐久性降低,甚至使得整个工程的竣工使用都受到了一定的制约。
【Abstract】Nowadays, steel energy plays an irreplaceable role in all kinds of construction and production, it supports the structure of buildings. In the use of steel bars, the general construction environment is relatively bad, and the weather conditions or improper storage will affect the quality of steel bars, and make surface of steel bar is corroded, but once the corrosion is serious, the whole quality and safety of the structure will be affected, at the same time, the durability of the structure will be reduced, and even the completion of the whole project will be restricted.
【关键词】钢筋防锈 ;锈蚀危害; 锈蚀治理
【Keywords】 steel bar rust prevention; corrosion hazard; corrosion treatment
【中图分类号】U321+.12 【文献标志码】A 【文章编号】1673-1069(2018)04-0150-02
1 工程簡介
青岛轨道交通R3线项目灵山卫停车场及出入段线工程位于青岛市黄岛区灵山卫街道,黄岛区地处华北暖温带季风区域内,属暖温带半湿润大陆性气候,受海洋影响,空气湿润,雨量充沛,温度适中,四季分明,有明显的海洋气候特点。年平均湿度在70%以上,累年7 月最大,可达92%,11 月最小为64%。陆上水面蒸发量1398.90mm,陆面蒸发量521.70mm。
本工程总占地面积约9.6万m2,承担全线部分停车列检任务,包括列车检运用库、洗车库、混合变电所、综合办公楼等生产、生活、办公设施。由于工程目前受变更等原因,停车场主变电所工程的基础以上部分设计图纸不完善,造成目前现场主变电站处于缓建状态,现场的预留钢筋防锈工作尤为重要。
2 钢材锈蚀原因
要找出钢筋锈蚀原因,需分析发生锈蚀的化学原理,钢材处于潮湿的空气中时,因其表面吸附作用,覆盖了一层极薄的水膜,这时钢材表面发生原电池反应,如果表面覆盖的水膜酸性很弱或者……