远红外热风输送系统在煤矿的应用和推广
2017-09-23翟展红
翟展红
【摘 要】《煤矿安全规程》规定:井筒进风井口以下的空气温度必须在2℃以上。安家沟风井使用远红外热风输送系统替代传统燃煤热风炉,目前已运行4个采暖季,经评估认为该系统具有初期投资少、运行可靠、运行费用低等优点,具有良好的示范性,从长远考虑,具有一定的经济、环境和社会效益,值得在其他煤矿推广应用。
【Abstract】 "Coal Mine Safety Regulations" stipulates that the air temperature under the air inlet of shaft must be above 2℃. In Anjiagou air shaft, we used far infrared hot air conveying system to replace the traditional coal-fired hot blast furnace, until now, it has run 4years, the assessment shows that it has the advantages of low initial investment, reliable operation, low operating cost, and has a good demonstration, in the long run, it has a certain economic, environmental and social benefits, is worthy to be promoted in other coal mines.
【关键词】远红外;热风;煤矿 ;推广
【Keywords】far-infrared; hot wind; coal mine; promotion
【中图分类号】DT82 【文献标志码】A 【文章编号】1673-1069(2017)09-0155-02
1 引言
《煤矿安全规程》第 137 条规定:“进风井口以下的空气温度必须在2℃以上”,而在我国北方,冬季气温都在0℃以下,寒冷气流致使井上井下温度相差无几,且持续时间长,必须对主井及副井进行热风输送,确保热风入井与冷风混合后,井内温度上升至5℃左右,井下方能正常生产,故煤矿井筒的保暖防冻工作尤为重要。
传统的井筒保暖采用燃煤锅炉产生的高温蒸汽或热水加热管道、燃煤热风炉产生热风再由鼓风机吹入井筒等方式进行供热,运行时间虽然只有5个月,但对空气的污染较大,运行成本又高,无论从经济还是环保角度考虑,选用清洁能源替代燃煤热风炉进行供热已成为一种必然趋势。我们通过市场调查,结合本公司矿井条件,对当下比较先进的远红外线空气加热、回风源热泵供热两种方案进行了比较,并在集团公司召开专题讨论会,最终确定采取远红外线空气加热方案。
本系统所使用的远红外线是波长范围为 4~1000 μm的电磁波,容易被有机物吸收,它本身并不是热,而是在被物质吸收后变成热,通过辐射传递为物质内部加热。……