APP下载

加气混凝土湿物理性质的测定

2016-05-31冯驰俞溪王德玲

土木建筑与环境工程 2016年2期

冯驰 俞溪 王德玲

摘要:分析建筑围护结构的热湿过程有着重要意义,而材料的物理性质是完成分析必不可少的参数。对中国常用多孔建筑材料而言,其湿物理性质并不完备。在20~25 ℃下,依据ISO和ASTM标准,通过平衡吸放湿实验、压力平板实验、蒸汽渗透实验、毛细吸水实验和真空饱和实验,对中国产B07级加气混凝土进行了测试,得到了包括等温吸放湿曲线、保水曲线、蒸汽渗透系数、液态水扩散系数、吸水系数、毛细饱和含湿量和真空饱和含湿量在内的所有湿物理性质。

关键词:加气混凝土;水分;储存函数;传递系数

中图分类号:TU111.2

文献标志码:A 文章编号:16744764(2016)02012507

Abstract: It is important to analyze the hygrothermal processes of building envelopes and the material properties are critical in the analysis. The hygric properties of the commonly used porous building materials in China are insufficient. Measurements on the B07level autoclaved aerated concrete are carried out at 20~25 ℃ based on ISO and ASTM standards of static gravimetric tests, pressure plate tests, cup tests, capillary absorption tests and vacuum saturation tests. All the hygric properties have been obtained, including sorption isotherms, the water retention curve, the vapor permeability, the liquid diffusivity, the capillary absorption coefficient, as well as the capillary and vacuum saturated moisture content.

Keywords:autoclaved aerated concrete; moisture; storage function; transport coefficient

建筑围护结构的热湿过程对建筑的耐久、能耗和室内环境有着非常重要的影响[13]。在分析建筑围护结构的热湿过程时,目前世界上较为先进的分析方法是将热量、空气和湿分(HeatAirMoisture,HAM)的储存与传递进行综合而非孤立的分析。欧美学者对此提出了多种数学模型,并已开发出了较为方便易用的软件,如WUFI和Delphin等。

无论采用何种模型来进行HAM分析,材料的物理性质都是必不可少的参数。在HAM分析中涉及到的物理性质可以分为3类[4]:基本物理性质(如密度、孔隙率等)、热物理性质(如导热系数、比热等)和湿物理性质(如蒸汽渗透系数、等温吸放湿曲线等)。在20世纪90年代到本世纪初,欧美国家通过IEA Annex 14[5]、IEA Annex 24[6]和ASHRAE 1018RP[7]等大型国际或地区项目,对大量常用建筑材料进行了测试,建立了包括上述各类物理性质的较为全面的基础数据库。

中国的常用建筑材料物理性质基础数据库主要由《民用建筑热工设计规范》GB 50176[8]和《建筑材料热物理性能与数据手册》[9]构成。……