200 MW级汽轮机喷嘴组技术改造
2016-01-26王艳
王 艳
(北京龙威发电技术有限公司,北京100044)
200 MW级汽轮机喷嘴组技术改造
王艳
(北京龙威发电技术有限公司,北京100044)
摘要:针对200 MW级汽轮机喷嘴组在设计、制造、安装方面存在的问题,在研究其调节级热力特性的基础上,通过全三维气动建模分析调节级各项损失产生的原因及影响因素,同时结合实际运行情况,寻求减少各项损失的途径,提出了喷嘴组优化改造的技术措施与方案:在动、静叶片的速度系数近似保持设计值不变的情况下,若调节级的密封情况良好,调节级的实际运行效率主要取决于压比、阀门开度和部分进汽度。调节级压比热力设计已确定,故认为在喷嘴组的改造设计时,应从减少调节阀门节流损失、降低调节级的部分进汽损失、减小调节级静叶栅的流动损失、完善调节级密封结构、改进喷嘴组加工精度等方面采取措施,提高调节级效率。实践证明,应用200 MW级汽轮机喷嘴组改造技术对喷嘴组实施改造,改造后设计工况下,调节级效率均高于未实施喷嘴组技术改造机组的10%~15%,部分负荷工况下的热力性能明显改善,节能效果显著。
关键词:200 MW级汽轮机;喷嘴组;技术改造;节能效果
中图分类号:TK264
文献标识码:A
DOI:10.3969/j.issn.1672-0792.2015.08.013
收稿日期:2015-05-22。
作者简介:王艳(1984-),女,工程师,从事汽轮机节能改造的研发、设计、技术支持等方面的工作,E-mail:wangyan@longwei.cn。
Abstract:To solve the existing problems with the 200 MW steam turbine nozzle set in aspects of design, manufacture and installation, this paper, on the basis of studying its thermodynamic properties, analyzed through three-dimensional aerodynamic modeling the reasons and influence factors about each loss on governing stage. Meanwhile, combined with the actual operation condition, the paper proposed technological measures and schemes on the optimal retrofit for nozzle set to reduce the loss: the speed coefficient of the moving and static blade approximately remaining unchanged, and the governing stage’s seal in good condition, the actual running efficiency of the governing stage is mainly determined by such factors as the pressure ratio, the open degree of valve and the degree of partial admission. The pressure ratio of governing stage having been determined during the thermal design, the retrofit design of the nozzle set should take measures to boost the efficiency of the governing stage from the reduction of the throttling loss of adjusting valve, of the loss of partial admission, of the flow loss of the static cascade, and the improvement of the seal structure of governing stage and of the processing precision of nozzle set. Practice showed that the governing stage efficiency for the reformed nozzle set for the 200 MW steam turbine, in the design conditions, was increased by 10%~15%, and that the thermal performance on part load conditions improved significantly with remarkable energy-saving effect.
Keywords:200 MW generic steam turbine; nozzle set; retrofit technology; energy-saving effect

0引 言
国内200 MW级机组在经历国家“上大压下”的节能环保政策后,目前在运机组均不同程度担任供热等任务,短期内不会关停,该等级机组在较长一段时间内会长期运行。……