APP下载

基于力敏传感器测无机盐溶液表面张力系数与浓度关系

2015-10-21许巧平

当代化工 2015年6期

许巧平

摘      要: 利用液体表面张力系数测定仪和力敏传感器测定了不同浓度的无机盐溶液的表面张力系数,并用origin做出浓度与表面张力关系图,得出在温度不变的条件下无机盐溶液的表面张力系数随浓度的增大而增大,并趋于一定值的结论。

关  键  词:力敏传感器、拉脱法;表面张力系数;浓度

中图分类号:TQ 028       文献标识码: A       文章编号: 1671-0460(2015)06-1203-03

Measuring the Relationship Between Surface Tension Coefficient

and Inorganic Salt Solution Concentration With Force Sensor

XV Qiao-ping

(College of Physics and Electronic Information, Yanan University, Shaanxi Yanan 716000, China)

Abstract: The surface tension coefficient of inorganic salt solutions with different concentrations were measured by the instrument for measuring the liquid surface tension coefficient and force sensor, and the relationship diagram between concentration and surface tension was drawn by Origin. The results show that the surface tension coefficient of inorganic salt solution increases with increasing of concentration under the same temperature, and tends to a certain value.

Key words: Instrument; Tearing-off method; Surface tension coefficient; Concentration

液體表面张力系数是表征液体性质的一个重要物理量,物质液体状态的许多性质都与液体的表面张力相关,如毛细现象、浸润现象等。因此,测量液体表面张力系数对于科学研究和实际应用都具有重要意义。液体表面张力系数的测定也是理工科学生要掌握的重要实验之一。为了加强了解影响不同液体的表面张力系数的因素,测量了两种不同浓度无机盐溶液表面张力系数。

1  实验原理

2  实验装置

图1为实验装置图,其中,液体表面张力系数测定仪包括硅扩散电阻非平衡电桥的电源和测量  电桥失去平衡时输出电压大小的数字电压表,其他装置包括铁架台、微调升降台、装有力敏传感器的固定杆、盛液体的玻璃皿和圆形吊环[2]。

图1  液体表面张力系数测定装置

Fig.1 Device for measuring the liquid surface tension coefficient

3  实验步骤

(1)调节仪器底座和传感器两端水平;接通组合测试仪电源,将仪器预热15 min。

(2)在玻璃器皿内放入被测液体并安放在升降台上。

(3)在传感器两端挂上砝码盘,调节电子组合仪上补偿电压旋钮,使数字电压表显示为零值。

(4)在砝码盘上依次加至0.500 g等质量的砝码6次,记录相应这些力作用下数字电压表的数值,填入表1中。……