APP下载

强夯地基施工及减振措施研究

2012-10-15苏倩杨晓慧

城市建设理论研究 2012年18期

苏倩 杨晓慧

[摘要]根据内蒙亿利能源达拉特分公司32万吨/年二期电石项目的强夯工程实例的现场实地试验数据,得出了强夯地基处理过程中,不同夯击能作用下振动加速度的递减规律;结果表明,隔振沟深度对隔振效果有效大影响,深度越深减振效果越好。在本工程设置的开挖隔振沟深度为2.5m。同时选用弹性模量远小于土体模量的填充材料,隔振效果达到了预期的效果。

[关键词]强夯,夯击能;隔振沟,减振效果

[ Abstract]: According to a Inner Mongolia Yili energy Dalate branch 320000 tons / year of two calcium carbide project dynamic engineering examples of the field test data, the dynamic compaction process, different compaction under the action of vibration acceleration is degressive the rule; the results show that, depth of isolation trench on the isolation effect of effective effect, the deeper the damping effect is better. In the present engineering setting of the excavation depth of isolation trench is 2.5m. At the same time selection of elastic modulus is much smaller than the soil modulus filler material, isolation effect to achieve the desired results.

[Key words]: dynamic compaction; compaction energy; vibration, damping effect

中图分类号:TU4文献标识码A 文章编号:

内蒙亿利能源达拉特分公司32万吨/年二期电石项目建址于内蒙古鄂尔多斯市达拉特旗三墒梁工业园区,地基处理工程设计采用强夯法。

1、地层结构及描述

按《岩土工程勘察规范》(GB 50021-2001)附录G的规定,拟建场地环境类型为I类。

根据详勘报告、钻探现场描述、原位测试结果及室内土工试验结果,将勘探深度范围内的地基土共分为6层;根据室内土工试验及原位测试结果综合分析确定各层土的地基承载力特征值fak及变形模量E0(压缩模量Es)见下表。

拟建场地地基土主要由粉细砂和粉质粘土组成。

在竖直方向上地基土工程性质差异较大,粉细砂①层呈松散状态;粉细砂②呈稍密~中密状态;粉细砂③层、粉细砂④层及粉细砂⑤均呈密实状态。各层粉细砂自上而下有随深度增加密实度逐渐增加,强度也随之提高。粉质粘土⑥层工程性质一般。

1#、2#电石炉主厂房工程重要性等级可按一级考虑。粉细砂①层的厚度在5.20~9.20m之间,设计拟建的建筑物基础将主要置于该层中。……