摘要:架空输电线路防雷是电力系统防雷工作的重要方面,常用的防雷措施有:架设避雷线、降低杆塔接地电阻、架设耦合地线、加强线路绝缘、采用不平衡绝缘方式、安装线路避雷器等。真正解决线路的雷电防护问题,还要从实际出发,因地制宜,综合治理,采取切实可行的方法,才能达到预期目的。
关键词:跳闸率;耦合地线;绝缘方式;耐雷水平
The overhead transmission lines and lightning protection
SunZongYi
(Meteorology Bureau of Pingyi City273300,China)
Abstract:the overhead transmission lines is lightning protection power system of the most important aspects of the lightning protection work, the commonly used lightning protection measures are: set up BiLeiXian, reduce the tower grounding resistance and laying coupling, and strengthening the line insulation wire, using the unbalanced insulation way, installation line lightning arrester, etc. Really solve the lines and lightning protection problems, but also from the reality, adjust measures to local conditions, the comprehensive management, take practical and feasible method, can achieve the desired result.
Key words: trip rate; Coupling ground; Insulation way; Lightning
中图分类号 :U463.62文献标识码: A 文章编号:
引言:架空输电线路是输电网及电力系统的重要组成部分。由于它暴露在自然之中,故极易受到外界的影响和损害,最主要一个方面就是雷击。电网中事故以输电线路故障占大部分,输电线路故障又以雷击跳闸占的比重最大。据运行记录,架空输电线路供电故障一半以上是由雷电引起的,所以防止雷击跳闸可大大降低输电线路故障,进而降低电网中事故的发生频率。有的架空线路虽装设了避雷线,但还是遭受雷击,产生供电故障,所以输电线路的防雷一般情况下要根据据具体情况选择一套完善的防雷措施,进行综合治理。经多年探索,目前输电线路防雷基本形成了一系列行之有效的常规防雷方法。
1、 架空输电线路的基本组成
架空输电线路由导线、避雷线、杆塔、绝缘子串和金具等主要元件组成。导线用来传导电流,输送电能;避雷线是把雷电流引入大地,以保护线路绝缘免遭大气过电压的破坏;杆塔用来支撑导线和避雷线,并使导线与导线间,导……