冰蓄冷在常州报业传媒大厦项目中的运用
2012-10-15孙燕
孙燕
摘 要:大型商场及办公中空调所消耗的电能是相当可观的,空调热负荷的高峰也是电负荷的高峰,对空调耗电量的控制就是对总电量的控制。采用冰蓄冷空调系统,可以转移制冷设备的运行时间,相当于把难以储存的电能实现了储存,这样就可以减小用户变配电设备的容量。随着国家电费政策向峰谷电价的倾斜,业主将会在运行费用上得到可观的实惠。
关键词:空调 冰蓄冷节能
Abstract: large shopping malls and office air-conditioning in the consumption of electricity is considerable, air conditioning heat load peak is also the electrical peak load of air conditioning, power consumption of control is to control total quantity. The use of ice-storage air conditioning system, can transfer the refrigeration equipment run time, equivalent to the stored electric energy to realize the storage, this can reduce the user variable power distribution equipment capacity. As the state of charge of electricity to the peak valley electricity price policy tilt, owners will be in operation costs are considerable benefits.
Key words: air conditioning, ice storage, energy saving,
中圖分类号 :TB494文献标识码: A 文章编号:
常州报业传媒大厦位于常州市重要的南北交通干道——和平中路东侧,清凉路以南。规划用地约17815平方米,南北长190米,东西宽从63米到159米。基地呈不规整L型、,东北侧是清凉小学,南面是清凉新村。
常州报业传媒大厦由三大功能组成:报社办公、商务办公和商业用房。报社办公大楼在最南端,为20层塔楼办公楼;商务办公大楼在北端,为28层塔楼;商业用房在中间,为一~四层裙房。总建筑面积:地上建筑面积69023㎡, 局部地下建筑面积24610㎡。报业办公楼20层,建筑高度83.4米;商务办公楼28层,建筑高度99.9米。
常州市室外温度分布如图:
室外设计参数见下表:
室内设计参数见下表:
根据以上常州市的气象条件及建筑室内温湿度要求,对空调冷负荷进行了逐时计算。
空调逐时冷负荷如图: