基于智能建筑论其空调自控系统
2012-06-04王晓
王晓
摘要: 空调设备可对房间或公共建筑内空气的温度、湿度、风速、洁净度等进行调节,满足人们在日常生活和工作中对空气质量的要求,创造一个温度适宜、湿度恰当、空气洁净的舒适环境。本文在认识智能建筑中空调自控系统的基础上,对目前空调控制系统的主要控制方法进行了论述。
关键词: 机组控制;新风机组;VAV空调系统;自动调节;控制
Abstract: the air conditioning equipment room or on public buildings of air temperature, humidity, wind speed, cleanliness of adjustment, satisfy people in daily life and work to the requirements of the quality of the air, and create a comfortable temperature, humidity and appropriate, air clean and comfortable environment. Based on the understanding of intelligent building air conditioning automatic control system, on the basis of the air conditioning control system at present the main control methods are discussed in this paper.
Keywords: unit control; The new wind generating units; VAV air conditioning system; Automatic regulation; control
中图分类号: TU831.3+5 文献标识码:A文章编号:
1空调自控系统
1. 1空调机组控制系统
空调机组控制系统包括新/回风阀门驱动器、风管式温/湿度传感器、过滤网压差报警开关、防冻报警开关、恒速风机、电动调节阀、配电装置和空调机组控制等硬件,包括新风、回风和送风等3个部分,主要实现的控制功能有:① 机组起/停;② 风机控制;③ 温度控制;④ 湿度控制;⑤ 新/回风阀门控制;⑥ 联锁控制;⑦ 报警。
1. 2新风机组控制系统
新风机组控制系统主要由新风阀门驱动器、风管式温/湿度传感器、过滤网压差报警开关、防冻报警开关、电动调节阀、恒速风机、配电装置和新风机组控制等硬件组成,包括新风、送风两部分,主要实现的控制功能有:① 机组起/停;② 风机控制;③ 温度控制;④ 湿度控制;⑤ 新风阀门控制;⑥联锁控制;⑦ 报警
1. 3变风量( VAV)末端控制系统
VAV末端控制主要实现的功能有:① 风机控制;② 温度控制;③ 湿度控制。
2VAV空调系统的控制方式
2. 1VAV空调系统的常规控制
目前,VAV空调系统采用的控制方式相对简单,每一台室外机对应若干台室内机(通常最大约为16台) ,各组VAV空调系统均独立运行控制,就地遥控器设置可按工程实现情况采用一个遥控器对应一台室内机,或一个遥控器对应若干台室内机,是一种比较经济实用的控制方式。……