钢桁腹-混凝土组合箱梁外接式节点疲劳性能试验研究
2025-08-11谭映梁祝兵崔圣爱毕昕宇张振卢宝洁
中图分类号:U443.35 文献标志码:A 文章编号:2096-6717(2025)04-0100-09
Experimental study on fatigue performance of external joints in steel truss web-concrete composite box girders
TAN Yingliang,ZHU Bing,CUI Shengai,BI Xinyu, ZHANG Zhen,LU Baojie (School of Civil Engineering,Southwest Jiaotong University, Chengdu 6loo3l,P.R. China)
Abstract: Two joint models with a scale of 1:3 were fabricated and fatigue tests were carried out to investigate thefatigue performance of steltrussweb-concrete composite external joints and verify the reliabilityof the new structure applied to high-speed railway bridges.The fatigue damage mode,load-displacement relationship,and load-strain curve of the composite external joints were investigated,the fatigue force characteristics of the external joints under different stress amplitudes were examined and the experimental results showed that the fatigue life of the composite external joint exceeds 2.51 millon loading cycles under the design stress amplitude, the joint is not damaged,the stiffess is not reduced,and the fatigue resistance performance meets the requirements.Under the action of 1.4 times design stress amplitude,the measured fatigue life of the external joint is1.4 milion times.The fatigue damage mode of the external joint is the cracking of the exposed gusset plate on the tensile side,and the critical detail of composite external joint is the welding detail which connecting the exposed gusset plate and the stifening plate.The fatigue crack causes the stress redistribution in the gusset plate,the strain in the gusset plate above and below the crack is reduced by 81% at most,and the strain in the gusset plate near the crack is increased by 33% at most. According to the S-N curve obtained by the one-point method,the fatigue life of the composite external joint corresponding to the design stress amplitude of 53.2MPa (204号 is 4.36 million times,which is 2.18 times of the design value.
Keywords: steel truss web-concrete composite bridge;composite external joint;model test;fatigue perfor mance; fatigue damage
钢-混凝土组合结构桥充分结合了钢材和混凝土的优势,具有优良的整体受力性能,得到了广泛应用[1-4]。钢桁腹-混凝土组合箱梁桥是近年发展起来的一种新型桥梁结构,由混凝土顶板、钢桁腹杆、混凝土底板及体内外预应力钢束等组成[5]。与混凝王箱梁桥相比,钢桁腹-混凝土组合梁桥采用钢腹杆代替混凝土腹板,规避了腹板开裂问题,减小了风力作用,减轻了上部结构自重,不仅增大了跨径,还减少了下部结构尺寸,获得了更优力学性能和景观效果。与钢桁架桥相比,混凝土顶底板的加入,增大了结构刚度,提升了桥梁抗扭转性能,增加了结构稳定性。因此,钢桁腹-混凝土组合结构桥被认为是非常有前景的新桥型,逐渐得到学者们的广泛关注[6-12]。近年来,中国先后建成了江山桥、德胜路桥、国道107宝安段匝道桥、深圳大学1号桥、水碾堡天桥等多座钢桁腹-混凝土组合结构公路桥梁,该桥型得到越来越多应用,但尚未应用于高速铁路桥梁。
钢桁腹-混凝土组合节点作为连接钢腹杆和混凝土顶(底)板的关键构造,其受力性能是保证桥梁安全性和可靠性的基石。学者们针对组合节点开展了大量研究。Furuichi等13设计了一种嵌入式(钢腹杆直接嵌入弦杆)钢盒节点,开展了缩尺比为1:2的静载破坏试验,结果表明,增大混凝土弦杆配筋率可以提升节点的抗剪刚度和强度,但会增大弦杆开裂破坏程度。Liu等4针对3种采用不同剪力连接件的嵌入式节点开展了疲劳试验,考察了节点的疲劳受力性能,结果表明,PBL剪力连接件节点的刚度变化比栓钉式节点小,具有更好的抗疲劳性能。……