栓钉连接双钢板-再生混凝土组合剪力墙抗震性能试验研究
2025-08-26韦芳芳韦芳芳陈卓然华子伟李丽萍
中图分类号:TU398.2 文献标志码:A
Abstract:To study the seismic performance of double steel plates and recycled concrete composite shear wals, three groups of quasi-static loading tests with varying shear-to-span ratios were designed and completed. A numerical model was established based on these experiments to investigate the impact of recycled agregate replacement rate and concrete strength on seismic performance.The test results indicated that the buckling phenomenon predominantly took place at thebottom of the specimens forthe structural steel plates,andthe shearto-spanratio emergedasacritical factor influencing thestructuralfailure.Astheshear-to一spanratio increased,the failure odeof thespecimens transitioned fromshear failure to flexuralfailure,accompanied bynoticeablebolt traces onthe surfaceof the steelplates.As the shear-to-spanratio was increased from1 to1.5and2,theultimate load was decreased by 25.9% and 45.0% ,respectively,while the displacement ductilitycoefficientwas increased by (20 9.2% and 29.7% ,and the equivalent viscous damping coefficient was increased by 26.0% and 89.3% . Each specimen exhibited a failure displacement angle ranging from 1/63 to 1/45 ,satisfying the seismic design code requirementsand demonstrating excellent deformation performance.Numerical simulations demonstrated that enhancing the strength gradeof recycled concretecan significantly enhance the initial lateral stiffnessand ultimate bearing capacity of the specimens.Both reducing the axial compression ratio and augmenting the strength of the external steel platescan enhance theshear capacity and lateral stiffessof the specimens.By considering the synergistic efects of concreteand steel platesand aligning withthe existing designcodes,acomposite shear wall calculation formula was proposed,incorporating an 8%~15% redundancy factor to ensure conservative and reasonable calculation outcomes.
Key words: structural engineering; structure design; seismic performance;studs connection;concrete aggregates;numerical analysis
再生骨料混凝土(再生混凝土)是由回收的废弃混凝土重新制备而成的节能环保材料[1],可用于主体承重结构构件,对推动建筑材料绿色减排进程有重要意义[2-3].
双钢板-混凝土组合(Concrete-filledDoubleSteelPlateComposite,CFDSPC)剪力墙作为高层建筑新型抗侧力构件,可通过减小构件截面尺寸,以较小墙厚满足高层及超高层建筑高轴压比、高承载力、高延性的需求[4-6],主要用于海洋工程和核电站工程.为探究CFDSPC剪力墙的性能和影响因素,许多学者从截面形式[8]、连接件类型[9]和内填混凝土[10-1]等方面展开研究,发现剪跨比[12]对试件耗能能力和破坏形态有较大影响,并通过加固试件底部提高延性3.通过已有研究可知,墙体性能与钢板、混凝土之间的连接方式有关,可通过缀板连接[14]栓钉连接等连接方式提高剪力墙延性[15].此外,内填再生混凝土对双钢板-再生混凝土组合剪力墙(Recycled Concrete-filled Double Steel Plate CompositeShearWall,RCFDSPC剪力墙)性能具有一定影响[16],例如结合绿色建材铁尾矿再生混凝土[17],其强度随着再生粗骨料率提高而下降,朱有华[18详细指出了粗骨料取代率范围对混凝土强度抗弯及抗剪承载力的影响.另外,还有学者研究钢板受力,通过双钢板带肋[19]和J型钩接头[20]方式提高结构延性和承载力,从而提升结构抗震性能.
本文开展了考虑不同剪跨比影响下再生混凝土双钢板-再生混凝土组合剪力墙的拟静力加载试验,并基于试验结果,采用ABAQUS建立数值模型,分析再生粗骨料取代率、再生混凝土强度等级、轴……