APP下载

国内外设备及管道绝热标准对比与分析

2025-08-03郝雨楠

标准科学 2025年13期
关键词:绝热材料保温厚度

Comparison and Analysis of Domestic and Foreign Standards for Thermal Insulation of Equipment and Pipes

HAO Yunan

(Institute of Technical Supervision and Research for Building Materials Industry of China)

Abstract:The thermal insulationof equipment and pipes playsacrucialrole in ensuring safeand stable operation,meeting process requirements,reducing heat (orcold)los,conservingenergy,andimproving economicefiency.There arestadards forthe design,construction,inspection,testing,and evaluationofequipmentand pipelineinsulationathomeandabroad.This papercompares British,Russan,Japanese and Chinesestandardsintermsofscope,insulationtypes,materialrequirements, insulationthicknesscalculation,andconstructionrequrements.Itanalyzesthedierences intechnicalrequirementsbetween Chinese and foreign standards and their underlying reasons,witha particular focus onthe allwable maximum heatlossAs a keyindicatorforevaluatinginsulatioefectivenessthealowable maximumheatlossisof greatsgnificance inachieving enrgy conservationandcarbonreductiongoals for equipmentand pipelines.Throughanalysis,thispaperaims toprovide insights for thedevelopmentofrelevanttandardsandpolicies,therebycontributing totherealizationofthecarbonpeakandneutralitygoals. Keywords: equipment and pipes; thermal insulation; standards comparison and analysis

0 引言

建筑中,大部分设备及管道都需要进行绝热处理,绝热效果关乎工艺安全稳定运行又对节能效果有重要影响。因此,国内外均制定了相关标准规范设备及管道广泛存在于我国工业领域和民用材料选用、绝热设计、绝热施工等环节,以保障绝热效果。我国现行设备及管道绝热标准中,GB/T4272《设备及管道绝热技术导则》是设备及管道绝热领域的重要基础标准,规定了设备管道绝热的基础通用要求,包括绝热设计、绝热厚度计算,材料的选择和性能要求、绝热结构的设计和施工、验收等与全流程内容。该标准被国内60余项国家、行业、地方和团体标准所引用,尤其是标准给出的允许最大散热损失量被引用最多,是最重要的一项技术指标,对绝热工程的设计和其节能效果评价有重要影响。

国外与设备及管道绝热相关标准较多,本文选择其中5项涉及绝热工程多流程内容并明确给出允许最大散热损失量的标准进行对比,包括欧洲标准BS 5422:2023《Thermal insulatingmaterialsforpipes,tanks,vessels,ductworkandequipment operating within the temperature range-40∘C to +700∘C ——Method for specifying》、BS 5970:2012《Thermal insulation of pipework,ductwork,associated equipment and other industrialinstallations in the temperature range of - 100∘C to +870∘C-Code ofpractice》、日本标准JISA9501:2019《保温保冷工程施工规范》、俄罗斯标准CII61.13330.2012(CHnII 41—03—2003)《设备和管道的隔热设计》。下文将就标准范围、绝热类型、绝热材料、绝热设计、允许最大散热损失量等方面分析国内外标准技术要求的差异,希望为相关从业人员进行国内外工程设计、施工、验收或效果评价提供帮助。

1 标准范围

随着绝热材料质量提升和新材料、新结构在工程的应用推广,绝热工程温度范围扩大,国内外相关标准、规范适用的绝热工程的温度范围均已体现该变化(见表1),调整了标准适用的设备、管道的温度范围。……

登录APP查看全文

猜你喜欢

绝热材料保温厚度
支护局部厚度不足对公路隧道运营耐久性的影响分析
少一维
人的脸皮真的会越活越厚吗
绿色建筑保温墙板中无机保温材料的应用探究
远安地堑地壳沉积层和基岩层厚度与 uP/νS 比值及其构造暗示
高层建筑外墙保温施工技术研究
极寒地区大型地下洞室利用射流风机除水雾模拟研究
新型气凝胶材料在建筑节能领域的应用探究
纳米绝热材料在绿色建筑中的应用现状与未来趋势