原子荧光法检测水中汞的方法验证
2021-10-31袁一丹王忠侠张笑
袁一丹 王忠侠 张笑



摘 要:根据国家环境保护标准《水质 汞、砷、硒、铋和锑的测定 原子荧光法》(HJ 694—2014),本文选用空白溶液、标准物质溶液以及实际樣品,用原子荧光光度计测定出几组数据,并经过计算,评定实验室开展水中汞检测的能力,即进行方法验证。验证的主要内容包括方法检出限、精密度和正确度。
关键词:原子荧光;汞;检出限;精密度;正确度
中图分类号:O657.31文献标识码:A文章编号:1003-5168(2021)15-0122-03
Abstract: According to the national environmental protection standard "atomic fluorescence method for the determination of mercury, arsenic, selenium, bismuth and antimony in water quality" (HJ 694-2014), this paper selected blank solution, reference material solution and actual samples, determines several groups of data with atomic fluorescence photometer, and evaluated the ability of the laboratory to carry out mercury detection in water through calculation, that is, method verification. The main contents of validation include detection limit, precision and accuracy.
Keywords: atomic fluorescence;hydrargyrum;method detection limit;precision;accuracy
汞俗称水银,在常温常压下以液态的形式存在,这在金属中是一个特例。汞及其化合物均为剧毒物质。汞及其衍生物有机汞,因具有持久性、易迁移性、高度的生物富集性和高生物毒性等特点,对人类健康和生态环境构成很大危害[1]。天然水中含汞极少,一般不超过0.1 μg/L。仪表厂、食盐电解、贵金属冶炼、温度计及军工等工业废水中可能存在汞,汞是我国实施排放总量控制的指标之一[2]。准确检测水中汞的含量,不仅是实现达标排放和排放总量控制不可或缺的手段之一,而且是实验室检测能力的重要体现。
为了保证实验数据准确可信,在正式使用某一标准方法进行检测前,应先进行方法验证。本次方法验证使用北京吉天AFS-810型双道原子荧光光度计,根据原环境保护部发布的环境保护标准《水质 汞、砷、硒、铋和锑的测定 原子荧光法》(HJ 694—2014),用空白溶液和有证标准物质以及实际样品分别测定出三组数据,根据相应公式计算出方法检出限、相对标准偏差及相对误差,判定结果是否符合质量控制指标的要求。……