常规心电图与动态心电图对起搏器植入术后患者心律失常的诊断比较
2021-09-10齐艳波
齐艳波
摘要:目的 比較常规心电图与动态心电图对起搏器植入术后患者心律失常的诊断价值。方法 选择2018年9月~2020年12月在我院接受起搏器植入的患者78例,按起搏部位分为右心室间隔(RVS)起搏组40例和右心室心尖(RVA)起搏组38例,两组在术中与术后均行常规心电图与动态心电图检查与诊断,观察起搏参数的变化与术后心律失常的发生情况。结果 所有患者起搏电极成功固定于RVA或RVS部位,两组的R波幅度、阻抗、电流、起搏阈值等比较差异无统计学意义(P>0.05)。术后RVA组的S-D时限为(0.034±0.001)s,S-R时限为(0.098±0.013)s,QRSd为(0.142±0.012)s;而RVS组分别为(0.033±0.002)s、(0.077±0.005)s、(0.116±0.009)s,RVS组的S-R时限与QRSd值显著少于RVA组(P<0.05)。动态心电图对窦性停搏、室性早搏等心律失常检出率要显著高于常规心电图(P<0.05)。以动态心电图作为金标准,RVS组术后心律失常与RVA组比较差异无统计学意义(P>0.05)。结论 动态心电图能及时观察到起搏器植入术后患者心律失常的发生,也能反映RVS与RVA部位起搏术中与术后的各项功能状况,为临床治疗与预后提供参考。
关键词:常规心电图;动态心电图;起搏器植入术;心律失常
[Abstract]Objective To compare the diagnostic value of routine ECG and dynamic ECG in patients with arrhythmia after pacemaker implantation. Methods 78 patients with pacemaker implantation in our hospital from September 2018 to December 2020 were selected and divided into right ventricular septum(RVs)pacing group(n = 40)and right ventricular apex(RVA)pacing group(n = 38)according to the pacing site. Routine ECG and Holter were performed in both groups during and after operation to observe the changes of pacing parameters and the occurrence of postoperative arrhythmia. Results all patients were successfully fixed to the RVA or RVs. There was no significant difference in R wave amplitude,impedance,current and pacing threshold between the two groups(P > 0.05). The S-D time limit of RVA group was(0.034 ± 001)s,S-R time limit was(0. 098 0 ± 013)s,qrsd was(0. 142 0 ± 0.012)s;In RVs group,(0.033 ± 0.002)s、(0.077 ± 0.005)s、(0.116 ± 009)s. The S-R duration and qrsd value in RVs group were significantly less than those in RVA group(P < 0.05). The detection rate of arrhythmias such as sinus arrest and ventricular premature beat in dynamic electrocardiogram was significantly higher than that in routine electrocardiogram(P < 0.05). There was no significant difference between RVs group and RVA group(P > 0.05). Conclusion Holter can timely observe the occurrence of arrhythmia in patients after pacemaker implantation,and can also reflect the functional status of RVs and RVA during and after pacemaker implantation,so as to provide reference for clinical treatment and prognosis.
[Key words]routine electrocardiogram;Dynamic ECG;Pacemaker implantation;Arrhythmia
隨着起搏器植入术的广泛增多,起搏器植入后的不良反应与负面效应也正在被人们所认识,特别是术后心律失常逐渐受到了关注[1-4]。术后心律失常可增加栓塞和死亡的危险性,为此早期发现心律失常对改善预后具有重要价值[5-7]。同时在临床上只有准确掌握起搏器的工作状态,才能及时调节起搏器的参数,给予患者及时的救治[8-9]。本文为此对比了不同心电图对起搏器植入术后患者心律失常的诊断价值,现报道如下。……