端屏蔽冷却系统堆腔最大补水速率估算
2021-07-28秦川张晓晖曾博文章鹏华
秦川 张晓晖 曾博文 章鹏华



DOI:10.16660/j.cnki.1674-098x.2101-5640-1497
摘 要:立足秦山三厂重水堆核电站经济高效地运行,本文介绍了端屏蔽冷却系统的功能与流程,分析了二号机组端屏蔽渗漏和一号机组108大修端屏蔽充水时间长的原因和结果,由此引出了对端屏蔽系统堆腔的最大补水速率的估算。
关键字:重水堆核电站 端屏蔽冷却系统 补水速率。
中图分类号:TL48 文献标识码:A 文章编号:1674-098X(2021)03(c)-0001-4
Estimation of Maximum Makeup Water Rate in Reactor Cavity of End Shield Cooling System
QIN Chuan ZHANG Xiaohui ZENG Bowen ZHANG Penghua
(China National Nuclear Power Co., Ltd., Jiaxing, Zhejiang Province, 314300 China)
Abstract: Based on high efficient and effective operation of Qinshan 3rd heavy water reactor, introducing the function and process of end shield cooling system, analyzing the reason and outcome of the leakage of unit 2 end shield and as well as 108 outage of unit 1 long time charging. Thus, the estimation of maximum water make-up rate of shield cavity has been brought up.
Key Words: Heavy water reactor nuclear power plant; End shield cooling system; Water make-up rate
1 概述
端屏蔽冷却系统是一个低温、低压的半封闭式轻水再循环系统,目的是排出堆腔和端屏蔽产生的热量,降低在反应堆周围的剂量率,以保护人员和设备。因此,维持系统装量、循环与冷却对保证核电站安全、可靠运行具有重要现实意义。通过估算端屏蔽系统堆腔的最大补水速率,结合经验数据,对今后运行人员相关操作具有一定的指导作用。
2 系统简述[1-3]
本系统是一条封闭的除盐水环路,由2台100 %容量的冷却泵驱动循环。在泵的出口,一部分流量流经2台各50 %容量的热交换器,与RCW换热后变成49 ℃的冷水,其中约342 m3/h流入堆腔,排出温度为54 ℃,约34.2 m3/h(每端)流过端屏蔽环并以54 ℃的温度进入堆腔。第二部分流量(340 m3/h)(每端)是热水和冷水的混合物,它以60 ℃供给端屏蔽,并以66 ℃排出。另外,有一小部分流量通過净化回路,然后返回到泵的入口。流量通过设在每条供水管线上的经过校准的孔板予以控制。冷却端屏蔽和堆腔后水流经一个40 s延迟箱,使短寿期的放射性同位素得到衰变。然后,水靠重力返回泵吸入口,而且在泵的吸入口有一个膨胀箱,以调节液位变化。……