正弦规成30?时角值误差的测量不确定度评定
2021-07-25马超董智
马超 董智



【摘要】 本文主要介绍了正弦规成30°角时角度误差的测量不确定度的评定,分析了测量结果不确定度的影响因素。为保障正弦规量值准确可靠提供一种技术手段,对安全生产和高质量制造具有一定指导意义。
【关键词】 正弦规;不确定度
【DOI编码】 10.3969/j.issn.1674-4977.2021.03.012
The Evaluation of Measurement Uncertainty of Angle Error When Sine Gauge is 30?
MA Chao1,DONG Zhi2
(1.Liaoning Institute of Measurement,Shenyang 110004,China;
2.Liaoyang Science and Technology Innovation and Entrepreneurship Service Center,Liaoyang 111000,China)
Abstract: This paper mainly introduces the evaluation of the measurement uncertainty of the angle error when the sine gauge is 30° angle,and analyzes the influencing factors of the uncertainty of the measurement results. It provides a technical means to ensure the accuracy and reliability of the sine gaugevalue,which has certain guiding significance for safe production and high quality manufacturing.
Key words: sine gauge;uncertainty
1 概述
正弦规是利用三角法测量角度的一种精密量具。一般用来测量带有锥度或角度的零件。因其测量结果,是通过直三角形的正弦关系来计算的,所以称为正弦规。它主要由一准确钢制长方体-主体和固定在其两端的两个相同直径的钢圆柱体组成。其两个圆柱体的中心距要求很准确,两圆柱的轴心线距离L一般为100 mm或200 mm两种。本文以测量1级中心距分别为200 mm和100 mm的正弦规为例,在0级平板上对其成30?时的角值误差进行不确定度评定。
2 测量依据
JJG 37-2005《正弦规检定规程》。其中所用00级标准平板在2013年新版检定规程JJG 117-2013《平板检定规程》中已经取消,故采用0级标准平板。
3 测量原理
用正弦定理算出正弦规成30°角度时所需要的量块高度,在0级平板上使用量块与正弦规组成30°角度,将30°专用角度块置于正弦规上,并靠紧两挡板,用测微仪测量与角度块接触点A、B两点的数值a和b(使A、B两点间距固定为70 mm),计算二者差值?h,然后通过相关公式计算来确定正弦规的角值偏差的不确定度。
4 数学模型
式中:[Δα]——正弦规角度偏差(");
[Δh]——测微仪在A、B两点处测得的高度差(mm);
[l]——测微仪在测量高度差时A、B两点的距离,本次取固定值70mm;
[L]——正弦规中心距(mm);
[ΔH]——标准量块的高度……