[摘    要] 针对中国实验快堆三回路除氧器三种水位计测量值相差较大的缺陷异常处理过程,通过对三种水位计的结构和测量原理分析,

得出造成各水位计测量值相差较大的原因,并提出提高水位测量精度的办法。

[关键词]中国实验快堆;除氧器;水位计

[中图分类号]TM62 [文献标志码]A [文章编号]2095–6487(2021)03–0–02

[Abstract]In this paper, aiming at the abnormal treatment process of the big difference in the measured values of three kinds of water level gauges in the three loop deaerator of China experimental fast reactor, through the analysis of the structure and measurement principle of the three kinds of water level gauges, the reasons for the big difference in the measured values of each water level gauge are obtained, and the methods to improve the accuracy of water level measurement are put forward.

[Keywords]China experimental fast reactor; deaerator; water level gauge

中国实验快堆三回路除氧器在反应堆启动前对三回路给水进行加热、除氧,并在反应堆运行期间储存并提供足够量的合格除盐水,反应堆启动、运行和停堆冷却期间,除氧器水温依靠启动锅炉蒸汽或核蒸汽维持在190 ℃的饱和温度。

1 除氧器参数监测仪表

除氧器设有温度监测、压力监测、水位监测仪表,出于反应堆安全可靠性排热要求,水位监测仪表既参与反应堆保护,也参与除氧器水位调节,水位监测设有就地仪表1台,水位调节仪表

1台,反应堆保护仪表6台。就地仪表为磁翻转水位计,引入三回路计算机监控系统的水位计为压差变送器,引入保护系统的6台水位仪表为压差变送器,6台压差变送器分为两组,每组3台压差变送器共用一套引压管。因此除氧器的8台水位计与除氧器水箱共有四套接管。保护系统的6台压差变送器两套接管位于除氧器南罐体两侧,另外两台水位计两套引压接点位于除氧器北罐体量侧,各接点位置如图1所示。

2 除氧器水位仪表的测量原理

除氧器的三种水位计,分别是就地磁翻转水位计、可调量程差压变送器和不可调量程差压变送器。……