余热锅炉烟气挡板液压执行机构损坏分析及处理
2020-10-21邱桂洲
邱桂洲



摘 要:文章介绍某9E燃气轮机电厂余热锅炉烟气挡板液压执行机构传动销轴断裂,关节轴承和隔套损坏的处理过程,对故障原因进行分析,提出一系列预防措施,对同类型机组烟气挡板检修维护有一定的参考作用。
关键词:余热锅炉;烟气挡板;液压执行机构;损坏分析
中图分类号:TM611.31 文献标志码:A 文章编号:2095-2945(2020)30-0119-02
Abstract: This paper introduces the treatment process of the transmission pin fracture of the hydraulic actuator of the flue gas baffle of the waste heat boiler in a 9E gas turbine factory, analyzes the causes of the failure, and puts forward a series of preventive measures, which can be used as a reference for the inspection and maintenance of the flue gas baffle of the same type of unit.
Keywords: waste heat boiler; flue gas baffle; hydraulic actuator; damage analysis
1 概述
某燃气-蒸汽联合循环发电厂建有2台9E燃气轮机组,配套2台余热锅炉和2台蒸汽轮机,每台余热锅炉进口烟道安装有烟气挡板,烟气挡板安装位置见图1,烟气挡板由液压油系统控制双边液压油缸驱动实现开关,液压油系统由液压油站、减压阀组、电磁阀、管路、蓄能器、油缸等组成,通过开关烟气挡板可以实现燃机单循环发电,也可实现整套联合循环机组发电。当余热锅炉或者蒸汽轮机故障需要检修时,可以关闭余热锅炉烟气挡板,燃气轮机排气从旁路烟囱排出,实现燃气轮机单循环发电,当整套联合循环机组无故障时,打开余热锅炉烟气挡板,实现整套联合循环机组发电。挡板几何尺寸5500*5500*200mm,挡板重量12745kg,燃气轮机排气流量1412t/h,燃气轮机排气压力2.5kPa。
2 事件经过
2017年11月2日7号锅炉停炉备用状态,锅炉检修技术人员定期对锅炉挡板进行静态开关活动检查,听见7号锅炉烟气挡板右侧(顺气流方向)液压油缸驱动杆有嘎嘎嘎的异常声音,经仔细检查发现挡板右侧上方液压油缸驱动杆销轴隔套断裂,拆开销轴,发现销轴折断,销轴和球头之间的关节轴承爆裂,见图2、3、4、5。……