RCW热交换器管板/传热管缺陷分析及应对措施
2019-03-25尤益辉胡胜
尤益辉 胡胜
【摘 要】RCW系统为电站反应堆厂房、辅助厂房、汽轮机厂房内包括慢化剂和停堆冷却器等几乎电站所有系统和设备的热交换器提供高质量的冷却水。RCW热交换器由于各种原因,管板/传热管产生冲蚀、锈蚀和穿孔等缺陷,传热管一旦泄露将降低系统换热效率以及设备可靠性,进而影响着电站的稳定运行。本文深入分析管板/传热管缺陷产生的原因,并对其失效机理进行研究。最后从生产实际出发,提出针对RCW传热管缺陷的应对措施,包括采用高分子涂层、加装尼龙套管和改变管板连接方式等措施。在一定程度上降低缺陷管产生,保证机组安全稳定运行。
【关键词】RCW热交换器;钛管;连接方式;胀接;焊接
中图分类号: TQ051.5文献标识码: A文章编号: 2095-2457(2019)02-0248-002
【Abstract】The RCW heat exchangers are the critical equipment of the power plant. The titanium tubes and heat exchanger tubes were corroded and plugged for some reason, which influenced the safety of the power plant. This paper deeply analyzed the reasons and failure mechanism of the tubes. Some measures were provided to deal with these defects from the viewpoint of the production practice in the end of this paper, which reduced the tube defects to some extent and ensured the plant run safely.
【Key words】The RCW Heat Exchanger; Titanium tube; Joint; Expanding; Welding
0 引言
RCW系統为电站反应堆厂房、辅助厂房、汽轮机厂房内包括慢化剂和停堆冷却器等几乎电站所有系统和设备的热交换器提供高质量的冷却水,RCW系统的热量通过RCW热交换器由海水带走。RCW热交换器由美国YUBA公司设计和制造[1],为单流程管壳式热交换器,管壳侧介质分别为海水和除盐水,设计寿命为40年,其主体结构如图1所示。
每台热交换器内置4932根钛管,管长14630mm、管径19.05×0.71mm、材质为ASTM B338 Gr.2级焊接薄壁钛管。管板为钛-碳钢复合板,厚度78mm;其中钛层厚度8mm、材质为ASME SB265 Gr.1标准钛板。RCW热交换器每根钛管均以材质为碳钢的12块支撑板和11块折流孔板支撑固定,管子两端由管板固定。管板与钛管之间采用胀接工艺,管板开有两道胀管槽,无密封焊[2-7]。……