荧光分光光度法测定斯达舒中铝的含量
2018-09-18王堃陈瑾赵春晓郭爱玲
王堃 陈瑾 赵春晓 郭爱玲
【摘 要】 目的:建立测定斯达舒中铝含量的新方法。方法:以萘甲醛席夫碱为络合剂,采用荧光分光光度法,在醋酸铵-醋酸(pH=7)的缓冲溶液中测定斯达舒中铝的含量。结果: 在激发波长为437 nm,发射波长为525 nm处,用荧光分光光度法对浓度0~6 μmol/L范围内铝离子标准溶液进行荧光强度的测定,结果表明荧光强度和浓度具有较好的线性关系,平均加样回收率为99.02%~102.03%,准确度较好。结论:该方法选择性好、灵敏度高、响应时间短、操作简便,适合于胃药斯达舒中铝含量的测定。
【关键词】 铝;荧光分光光度法;斯达舒
【中图分类号】R914.1 【文献标志码】 A 【文章编号】1007-8517(2018)08-0034-03
Abstract:Objective To establish a new method for the determination of aluminium in Si Dashu. Method The content of aluminum in Si Dashu was determined in ethanoic acid-ammonium acetate cushion fluid ( pH=7) with naphthalene formaldehyde Schiff base as complexing agent by fluorescence spectrophotometry. Result The calibration curve of aluminum ion with good linearity was obtained over the range of 0-6 μmol/L at the excitation wavelength of 437 nm and the emission wavelength of 525 nm. The recovery rate was 99.02%~102.03% with good accuracy. Conclusion The method has the advantages of high sensitivity, selectivity, short response time and simple operation. The method was suitable for determining the aluminum content in Si Dashu.
Keywords:Aluminum; Fluorescence Spectrophotometry; Si Dashu
鋁是地壳中含量最丰富的金属元素,约占地壳的70%,在许多药物、食品添加剂、混凝剂等中都含有铝。铝是一种对人体和生态都有害的物质,虽然快速进入人体不会导致急性中毒,但是长期过量的摄入铝会对中枢神经、肝、肾、骨、造血细胞都有损坏,导致痴呆,引起贫血、骨质疏松等疾病[1]。所以,建立一种灵敏、快速的分析方法用来检测铝的含量具有一定的实际意义。目前,测定铝的方法有原子吸收光度法[2]、化学法[3]、紫外分光光度法[4]等。而荧光光度法因具有操作简单快速、样品用量少、灵敏度高、选择性好等优点,被广泛地应用于铝的含量测定[5]。在前期研究中,以2-氨基苯酚和2-羟基萘甲醛为原料,合成了萘甲醛席夫碱(HPIN),并通过荧光分光光度法测定了白术、防风、黄芪、连翘等中药中铝的含量[6-7]。本文探索以HPIN为络合剂,采用荧光分光光度法测定胃药斯达舒中铝的含量,为复方制剂中铝含量的测定提供了一种新的方法,为斯达舒质量控制的检测方法提供参考。……