某核电机组自然循环分析及规程改进
2018-04-16魏君安孙超王鸡换何斌
魏君安 孙超 王鸡换 何斌
【摘 要】针对某核电机组的实际运行情况,结合建厂初期自然循环流量试验,通过运用Matlab软件模拟计算,给出了反应堆停堆后自然循环流量和热段温升随时间的变化趋势,以及针对这一趋势特点提出几点改进应急EOP规程的建议。
【关键字】自然循环;强迫循环;汽腔
中图分类号: TK124 文献标识码: A 文章编号: 2095-2457(2018)03-0159-003
The analysis of the natural circulation and improving the EOP rule in a nuclear Plant
WEI Jun-an SUN Chao WANG Ji-huan HE Bin
(Nuclear Nuclear Power Operations Management Co., Ltd., Jiaxing, Zhejiang 314300, China)
【Abstract】According to the actual situation of a nuclear Power Plant, linking to the experiment of the natural circulation in the early found the nuclear Power Plant, and using the software of Matlab to simulated calculation, we get some operation data about the natural circulation flow and the hot part temperature rise trend with the time. According to this trend, we also give some suggestion that it can improve EOP rule.
【Key words】The natural circulation; The forced circulation; Chamber
0 背景
自從福岛事故之后,核电厂的安全越来越成为公众关注的焦点。非能动设备和运行方式的研究也成为后福岛时代核电厂设计的原则。自然循环是指在闭合系统中不依赖外界动力源,仅仅由冷热流体间的密度差形成的浮升力驱动流体循环流动的一种能量传输方式。某核电机组设计于上世纪80年代,一回路采用两回路堆芯冷却方式,在主泵故障和全厂失电或破口事故情况下,堆芯的自然循环能力大小直接影响反应堆的固有安全性。
本文通过对某核电机组停堆后自然循环流量的分析,给出了一些建议,仅供参考。
1 影响自然循环的因素
1.1 位差
取决于反应堆堆芯和蒸汽发生器直接的高度差。位差在设计时就已经确定,某核电机组堆芯和蒸汽发生器的位差是9.935m,其对自然循环能力的影响是固定的有限的
1.2 密度差
密度差主要是由于堆芯热段与冷段之间的温度差引起的,温差越大自然循环能力也就越强。
1.3 回路中的含汽率
自然循环是闭合回路,如果当中某一段出现了汽化,使得汽体阻碍了自然循环的路径,自然循环将会中断。……