某核电厂汽轮机低压转子膨胀异常分析与处理
2018-04-16王犇刘东亮赵书宇
王犇 刘东亮 赵书宇
【摘 要】介绍了某核电厂汽轮机低压转子膨胀监测值超过设计报警阈值的问题。通过分析和检查,得出问题的根本原因是低压转子在汽轮机轴封蒸汽加热作用下发生轴向膨胀,且该膨胀量远大于转子低速旋转时泊松效应造成的轴向收缩量。现场制定、实施了解决方案,经验证该方案解决了汽轮机低压转子膨胀监测值超过设计报警阈值的问题。
【关键词】核电厂;汽轮机低压转子;膨胀;报警;降温
中图分类号: TM623.3 文献标识码: A 文章编号: 2095-2457(2018)03-0144-003
Analysis and Solutions for Turbine Low-pressure Rotor Abnormal Expansion at a Nuclear Power Plant
WANG Ben LIU Dong-liang ZHAO Shu-yu
(China Nuclear Power Engineering Co., Ltd, Guangdong Shenzhen 518124, China)
【Abstract】The paper introduces the problem of turbine low-pressure rotor monitor value was greater than design alarm threshold at a nuclear power plant. Through analysis and inspection, the root cause of the problem is low-pressure rotor under the effect of turbine shaft seal steam heating generate axial expansion, and this expansion value is greater than the axial shrinkage value which caused by Poisson Effect when turbine low-pressure rotor rotates at low speed. Develop and implement solutions for the problem which was solved after verification on site.
【Key words】Nuclear power plant; Turbine low-pressure rotor; Expansion; Alarm; Cooling
0 引言
某核電厂使用HN1119-6.43/280/269-H型汽轮机,该汽轮机为饱和蒸汽、单轴、四缸、六排汽、中间再热、冲动凝汽式半转速机,由1个高中压合缸和3个双流道、双排汽低压汽缸组成。机组设置有一个汽轮机低压转子膨胀监测通道(GME315MV)以监测3个低压转子刚性对接后整体相对汽轮机轴系死点位置的轴向膨胀量,用于指示低压汽缸内轴向动、静部件的间隙变化。该核电厂GME315MV设计一级报警(GME313KA)阈值为18.5mm,二级报警(GME413KA)阈值为19.5mm,其中GME413KA为建议手动停机报警信号。报警触发代表低压汽缸内轴向动、静部件间隙超出设计许可范围,动、静部件可能因此发生机械摩擦,因此汽轮机低压转子轴向膨胀监测值对汽轮机运行安全而言有重要指示作用[1-2]。
该核电厂GME315MV安装完成后在汽轮机在静止工况下的监测值正常,当汽轮机主盘车启动,投运汽机轴封系统(CET)和凝汽器真空系统(CVI)后GME315MV监测值逐渐增大至22.5mm,因监测值超过报警阈值,系统先后自动触发GME313KA和GME413KA。……