城市轨道交通交流供电系统经济性浅析
2017-10-25汪润泽
汪润泽


【摘 要】我国城市轨道交通发展突飞猛进,但其采用的直流供电系统的缺陷不可避免,如杂散电流危害、直流电机换向困难、共用中压环网影响等。论文介绍了城市轨道交通交流供电系统,并与既有的直流牵引系统比较,从主变压器容量、主变电所数量、环网电缆用量、地下车站建设、运营检修成本方面,浅析了城市轨道交通交流供电系统的经济性。
【Abstract】The development of urban rail transit in our country is advancing by leaps and bounds, but the defects of the DC power supply system are inevitable, such as stray current hazards, DC motor commutation difficulties, and the effects of common use of medium voltage ring networks and so on. This paper introduces AC power supply system for urban rail transit, compared with the DC traction power system, and based on the main transformer capacity, the number of main substation, the amount of cable network cable, the construction of underground station and the cost of operation and maintenance, the economy of urban rail transit power supply system is analyzed.
【关键词】交流供电系统;主变电所;电缆环网;经济性
【Keywords】AC power supply system; main transformer substation; ring network power cable; economy
【中图分类号】U21 【文献标志码】A 【文章编号】1673-1069(2017)09-0052-02
1 既有城市轨道交通牵引供电系统及弊端
1.1 既有城市轨道交通牵引供电系统
我国现有城市轨道交通供电系统是城市电网的一个用户,直接从城市电网取得电能。采用集中供电的直流供电方式(以下称直流供电),在城市轨道交通沿线,根据用电容量和线路长短,建设专用的主变电所,主变电所应有两路独立的进线电源。主变电所进线电压一般为110kV,经降压后变成35kV,经电缆环网,沿线路、隧道敷设至地下车站的牵引变电所与降压变电所。牵引变电所将35kV牵引变降压并经24脉整流得到1500V直流,经接触网对地铁电客车供电,走行轨回流方式。降压变电所从中压环网取电,降压为0.4kV,对车站所有用电设备供电。[1]
1.2 直流供电方式的弊端
杂散电流(迷流)将对地铁中供电网的电气设备、设施的正常运行造成不同程度的影响,以及对基础工程的隧道、道床的结构钢和附近的金属管线造成危害 。
地铁电客车的频繁启停和很大的行车密度,不利于电客车直流电机的换向,而使用VVVF逆变器驱动的三相鼠笼式异步电机,也存在电客车设备复杂等缺点。……