APP下载

阶梯电压下变压器匝间绝缘局部放电试验研究

2017-07-10魏新劳裴震聂洪岩李林骜王永红陈庆国

电机与控制学报 2017年7期
关键词:电力变压器

魏新劳 裴震 聂洪岩 李林骜 王永红 陈庆国

摘要:对于变压器绕组而言,轻微匝间放电的发展可能会造成匝间短路甚至更严重的后果。因此,对变压器绕组匝间局部放电的发展进行深入研究具有重要意义。在实验室内构建了变压器匝间绝缘局部放电试验平台,参照500kV电力变压器线圈绝缘处理工艺要求,设计并制作了匝间绝缘局部放电试验模型线圈,采用逐级升压法对模型线圈施加试验电压,利用数字式局部放电检测仪进行局部放电信号采集,在室温下对变压器匝间绝缘局部放电特征量和二维图谱信息进行了系统的研究。得出了不同加压持续时间下脉冲最大幅值、脉冲平均幅值、脉冲重复频率和脉冲功率的变化特征以及二维图谱的相位分布信息。

关键词:电力变压器;匝间绝缘;局部放电;特征参量;二维图谱

DOI:10.15938/j.emc.

中图分类号:TM85文献标志码:A文章编号:

Partial discharge tests and researches in power transformer interturn insulation under step-stress

WEI Xin-lao,PEI Zhen,NIE Hong-yan,LI Lin-ao,WANG Yong-hong,CHEN Qing-guo

(College of Electrical and Electronic Engineering,Harbin University of Science and Technology,Harbin 150080,China)

Abstract:For the transformer winding, slight inter turn discharge may cause inter turn short circuit or even more serious consequences. Therefore, it is significant to study the development of partial discharge in transformer windings.Transformer turn to turn insulation partial discharge test platform was constructed in this paper, reference 500kV power transformer coil insulation processing requirements, designed and fabricated interturn insulation partial discharge test model coil, step-stress tests were applied to coil models, the digital partial discharge detector was used for partial discharge signal acquisition, interturn partial discharge characteristics, two-dimensional phase distribution were studied at room temperature.From the results, the variable characteristics of the pulse maximum magnitude and average magnitude, pulse repetition rate, pulse power and partial discharge messages of two-dimensional phase distributioncan be obtained in step-stress tests of different step-up keeping time.

Key words:power transformer;interturn insulation;partial discharge;characteristic parameter;two-dimensional phase distribution

0引言

大型电力变压器在电力系统中处于核心地位,其安全稳定运行对于整个电网及社会生活至关重要[1]。大量统计表明,绝缘缺陷是造成变压器故障的主要原因[2-4]。对于绕组内绝缘,绝缘缺陷发展迅速,一旦发生事故将对整个电网带来难以估量的后果[5]。

采用局部放电对绝缘状态进行检测已得到了国内外行业的普遍认同[6-8]。传统局部放电特征参量(脉冲最大幅值、脉冲平均幅值、脉冲重复频率等)已得到广泛研究,随着计算机及数字化技术的发展,局部放电图谱及相关统计参数研究受到了国内外学者越来越多的关注[9-10]。……

登录APP查看全文

猜你喜欢

电力变压器
局部放电产生的原理探讨
大型电力变压器过热性故障诊断与处理
简述电网功率因数的提高方法和意义
电力变压器常见故障与继电保护方法探究
大型电力变压器直流偏磁现象分析
关于电力变压器高压试验的探析
电力变压器高压试验技术及故障处理
配电网电力变压器故障分析研究
电力变压器高压试验技术分析
电力变压器安装调试技术分析