APP下载

水幕隔热阻断效果数值模拟

2017-06-06姚建芳

中国建筑科学 2017年5期

摘 要:本文对引起烟气运动的原因进行分析,通过PyroSim软件建立长20m的走廊模型,运用FDS软件对设置6种水幕设置方式的工况进行模拟,讨论分析不同设置方式下水幕对建筑走廊中烟气的隔热阻断效果。模拟结果表明:水幕的开启能够有效地减缓烟气的流动速度及对被保护侧的空间起到隔热降温的效果,在走廊顶部设置水幕及在顶部和地面同时设置水幕的方式能够更好地为人员逃离火灾现场及为消防人员灭火争取宝贵的时间。

关键词:安全工程;建筑走廊;水幕;烟气运动;烟气温度

Abstract:In this paper, the causes of smoke movement is analyzed, 20m long corridor is established by PyroSim software.FDS software is used to simulate the smoke movement in six kinds of water curtain working condition. The effect of water curtain blocking smoke ability in building corridor is discussed under different kinds of water curtain setting condition. Simulation results show that the water curtain can effectively reduce the smoke moving velocity, it also can insulate heating and cool down the protected space temperature. Water curtain set at the top single and both of the top and the ground in the building corridor can win more precious times for the firefighters to extinguish the fire. so as the trapped people can quickly flee the scene of the fire.

Key words:safety engineering; building corridor; water spray; smoke movement; smoke temperature

前言

随着我国经济建设的发展,高层建筑不断增多,带来的火灾隐患也越来越大。在众多建筑火灾中,火灾危害主要是热量、烟氣和缺氧三种因素共同作用造成的[1]。近年来水幕作为一种常见的阻火隔热手段,应用到了高层建筑防烟的设计中,所谓消防水幕是指将水喷洒成水帘幕状,用以阻止火灾烟气穿过开口部位,从而防止火灾蔓延的一种消防设备[2]。

魏东[2-3]等人对防火分隔水幕的隔热机理及辐射衰减模型进行了分析与求解,钟涛[4]等人对大跨度、高空间的水幕进行了一系列的全尺寸试验研究,得出用水量、水幕厚度及水幕水滴的密集程度和均匀性是影响水幕效果的主要因素,段云、王新[5-6]等人针对水幕在隧道中的灭火阻烟效果进行了数值模拟,验证水幕在隧道中能够使隧道内烟雾的温度降低,但是由于水幕的作用,使隧道内的CO浓度增加,对隧道内人员的逃离产生不利的影响。……