APP下载

探讨不同MRI检测方法在评估子宫内膜癌患者深肌层浸润中的临床价值

2017-03-28赵凤宇

中国实用医药 2017年5期

赵凤宇

【摘要】 目的 比較不同核磁共振成像(MRI)检测方法在评估子宫内膜癌患者深肌层浸润中的临床价值。方法 50例子宫内膜癌患者, 分别对其采用T2加权信号(T2WI)、增强T1加权信号(CE T1WI)和弥散加权信号(DWI)等方法行MRI扫描检测, 评估深层肌层浸润程度, 并将其与手术病理结果进行对比。结果 50例子宫内膜癌患者中, 34例患者经手术病理证实为有肌层浸润, 占68.0%;16例患者经手术病理证实为无肌层浸润, 占32.0%。经T2WI检测有肌层浸润的准确性为80.0%, 敏感性为88.2%, 特异性为62.5%, 阳性预测价值为83.3%, 阴性预测价值为71.4%;经CE T1WI检测有肌层浸润的准确性为78.0%, 敏感性为82.4%, 特异性为68.8%, 阳性预测价值为84.8%, 阴性预测价值为64.7%;经DWI检测有肌层浸润的准确性为82.0%, 敏感性为91.2%, 特异性为62.5%, 阳性预测价值为83.8%, 阴性预测价值为76.9%;经T2WI和CE T1WI联合检测的准确性为90.0%, 敏感性为94.1%, 特异性为81.3%, 阳性预测价值为91.4%, 阴性预测价值为86.7%;经T2WI和DWI联合检测的准确性为96.0%, 敏感性为97.1%, 特异性为93.8%, 阳性预测价值为97.1%, 阴性预测价值为93.8%。T2WI和DWI联合检测的准确性、敏感性、特异性以及阳性预测价值、阴性预测价值均明显高于其他检测方法, 差异均有统计学意义(P<0.05)。结论 T2WI和DWI联合检测能够更好的显示子宫内膜癌深肌层浸润程度, 可以为临床诊断提供可靠的依据, 提高诊断准确率。

【关键词】 子宫内膜癌;核磁共振成像;深肌层浸润程度;准确性;特异性

DOI:10.14163/j.cnki.11-5547/r.2017.05.019

Investigation of clinical value by different MRI detection measures in evaluation of deep myometrial invasion in endometrial cancer patients ZHAO Feng-yu. Tieling County Central Hospital, Tieling 112000, China

【Abstract】 Objective To compare clinical value by different magnetic resonance imaging (MRI) detection measures in evaluation of deep myometrial invasion in endometrial cancer patients. Methods A total of 50 patients with endometrial cancer all received MRI scanning detection by T2-weighted imaging (T2WI), enhanced T1-weighted imaging (CE T1WI) and diffusion weighted imaging (DWI). Evaluation was made on deep myometrial invasion degree to compare with surgical pathological outcome. Results Among the 50 patients with endometrial cancer, there were 34 cases with confirmed myometrial invasion by surgical pathology, accounting for 68.0%, and 16 cases without confirmed myometrial invasion by surgical pathology, accounting for 32.0%. T2WI in detection of myometrial invasion showed accuracy as 80.0%, sensitivity as 88.2%, specificity as 62.5%, positive predictive value as 83.3%, and negative predictive value as 71.4%. CE T1WI in detection of myometrial invasion showed accuracy as 78.0%, sensitivity as 82.4%, specificity as 68.8%, positive predictive value as 84.8%, and negative predictive value as 64.7%. DWI in detection of myometrial invasion showed accuracy as 82.0%, sensitivity as 91.2%, specificity as 62.5%, positive predictive value as 83.8%, and negative predictive value as 76.9%. Combination of T2WI and CE T1WI in detection of myometrial invasion showed accuracy as 90.0%, sensitivity as 94.1%, specificity as 81.3%, positive predictive value as 91.4%, and negative predictive value as 86.7%. Combination of T2WI and DWI in detection of myometrial invasion showed accuracy as 96.0%, sensitivity as 97.1%, specificity as 93.8%, positive predictive value as 97.1%, and negative predictive value as 93.8%. Combination of T2WI and DWI had obviously higher accuracy, sensitivity, specificity, positive predictive value and negative predictive value than other measures, and their differences all had statistical significance (P<0.05). Conclusion Combined detection by T2WI and DWI can precisely show deep myometrial invasion degree in endometrial cancer. This method can provide creditable reference for clinical diagnosis and improve diagnostic accuracy rate.

【Key words】 Endometrial cancer; Magnetic resonance imaging; Deep myometrial invasion degree; Accuracy; Specificity

子宫内膜癌属于恶性肿瘤, 是临床上比较常见的一种女性生殖系统疾病。近年来, 随着生活方式的改变, 再加上女性所面临的生活及工作压力增大, 子宫内膜癌的发病率呈逐年上升趋势[1-3]。由于临床上子宫内膜癌需要根据癌症分期来选择相应的治疗方案, 因此术前分期非常重要[4, 5]。……

登录APP查看全文