架空输电线路覆冰危害预防措施分析
2017-03-10秦文祥��
秦文祥��
【摘要】架空输电线路覆冰对电网有着很大的危害,进而对电网运营和经济发展造成很大的负面影响,导线发生覆冰后易;诱发舞动,其脱冰引发的导线跳跃也容易致使断线、倒塔等事故发生。为使高压电网安全可靠地运行;对输电线路覆冰形成机理的研究以及覆冰荷栽下的力学研究是一个重要课题。
【关键词】预防;架空输电线路;覆冰;除冰
Analysis on Precautionary Measures of Ice Damage on Overhead Transmission Line
Qin Wen-xiang
(Yunnan Silver Tower Power Construction Co., LtdKunmingYunnan650000)
【Abstract】Overhead transmission lines on the grid has a great harm to the grid, and thus the operation of the power grid and economic development caused a great negative impact, the wire after the ice is easy; induced dancing, the ice caused by the ice jump is also easy to cause disconnection, Inverted tower and other accidents. In order to make the high voltage power grid safe and reliable operation, it is an important task to study the formation mechanism of the icing process of the transmission line and the mechanics of the ice cover.
【Key words】Prevention;Overhead transmission lines;Ice
2008年1月10日以來,我国南方大部分地区出现了历史罕见的低温、雨雪冰冻天气。给输变电设施带来大面积覆冰。雪灾导致国家电网直接经济损失高达104.5亿元。正确认识电网覆冰的危害,加强和改善线路的抗覆冰能力对保证电力线路安全、提高电网可靠性具有至关重要的作用。
1. 输电线路覆冰危害的特点
1.1线路覆冰倒杆(塔)断线的特点。
线路覆冰倒杆(塔)断线的特点:一是由于覆冰时杆(塔)两侧的张力不平衡造成的。在一些地形起伏较大的地区,两相邻的杆(塔)在高度和距离上存在很大的差距,在还未覆冰时两侧就形成了较大的不平衡张力,当线路上出现大密度的覆冰时,杆(塔)两侧的不平衡张力加剧,当张力不断加大,直至到达杆(塔)、导线所能承受的极限时,就出现了导线断落或杆(塔)倒塌的现象。因此,在灾后恢复和未来的设计改造中,应尽量避免大高度差、大距离和大转角。二是线路上有大密度的雨凇覆冰时,因为雨凇覆冰是“湿”度增长过程,其粘附能力强,不易掉落。在风的激励下,导线会产生大振幅、低频率的自激振动。……