An Inquire into the Energy-conservation Design of the Underground Garage Lighting
2016-07-14LiuLihongXuHuaWuYiGuoHongyan
Liu Lihong / Xu Hua / Wu Yi / Guo Hongyan
An Inquire into the Energy-conservation Design of the Underground Garage Lighting
Liu Lihong / Xu Hua / Wu Yi / Guo Hongyan
AbstractThe paper firstly analyzes the different requirements of the new and old lighting standards for the underground garage lighting design. On this base, two kinds of energy-conservation scheme on underground garage lighting design are elaborated: traditional design scheme and design scheme on using LED lamp. Subsequently, the paper makes a comparison between the two energy-conservation design schemes.
Keywordsgarage lighting, luminance, LED lamp
0引言
随着国内经济的迅速发展,城市机动车数量增多和建筑用地面积缺乏的矛盾使得地下车库成为现代建筑不可缺少的配套设施。在进行地下车库设计时,采光方面具有较大的局限性,这些因素使得地下车库照明节能设计在电气设计中受到重视。
GB 50034-2013《建筑照明设计标准》于2014年6月正式实施,对车库照明提出了新的要求;中国照明学会于2014年7月发布《地下车库智能照明技术指导意见》试行稿,对地下车库智能照明提出技术指导意见。总结以上情况,本文对新建建筑地下车库的照明节能设计进行了相关探讨,阐述了常用的照明节能设计方案。
1车库照明设计新标准
GB 50034-2013《建筑照明设计标准》(简称“新规范”)对车库照明提出了新标准,与GB 50034-2004(简称“旧规范”)相比,关于车库照明部分的新、旧规范调整如表1所示。
由表1可知,对于住宅建筑、公共建筑和工业建筑,“新规范”中的车库照度和功率密度均小于“旧规范”中相应数值。
车库作为存放车辆的场所,其照度主要为满足平时卫生清扫、设备维护及司乘人员安全,而车库人员活动需要的是局部照明,对整体照度要求不高;同时,在一些按照75lx进行照度设计并已投入运行的工程案例中,物业管理人员在使用的过程中常对灯具进行分组控制,因此长时间使用的灯具照度实际值均小于设计值的75lx,根据对此类车库项目中物业管理人员和司乘人员的工程回访了解,通过分组控制适当地减少灯具、降低照度并未感觉有明显不适或差异。……
杂志排行
智能建筑电气技术的其它文章
- Application of Navigation System Based on iBeacon Technology in Tourist Attractions
- Design and Application of Security and Protection System of Residential Park Project
- Optimization of Power Distribution System of Fire Fighting Equipment
- Electrical Design of Electric Vehicle Charging Facilities for Civil Building
- Analysis of Reactive Measurement in an Industrial Park
- Promoting the Use of LED Lighting from the Design Stage