[摘要]目的探究尿干化学分析仪与尿有形成分分析仪联合检测尿路感染的临床应用价值。方法整群选取2014年3月—2015年3月期间在该院收治的260例标本检测患者作为研究对象,将白细胞计数、细菌计数、亚硝酸盐试验结果同细菌培养进行比较。结果①细菌计数敏感性(50.76%),特异性(77.83%),阳性预测值(60.18%),阴性预测值为(82.69%)相较于三项联合敏感性(80.01%),特异性(82.21%),阳性预测值(64.32%),阴性预测值(86.51%)明显较低,差异有统计学意义(P<0.05),②白细胞计数在上述有关方面相较于三项联合指标差异有统计学意义(P<0.05);③亚硝酸盐在上述有关方面相较于三项联合指标差异有统计学意义(P<0.05)。结论采用尿干化学分析仪与尿有形成分分析仪联合检测方法,对尿路感染的诊断具有较高的灵敏度,在保证检测结果科学、准确的同时,提升了工作效率,可在较大程度上排除尿路感染,值得在临床上大范围推广和应用。
[关键词]尿路感染;尿干化学分析仪;尿有形成分分析仪
[中图分类号]R446.12
[文献标识码]A
[文章编号]1674-0742(2015)10(a)-0028-03
[作者简介]赵飞(1983.9-),男,江苏邳州人,本科,检验师,研究方向:微生物。
Abstract[]Objective To explore the clinical value of urine dry chemistry analyzer and urine formed element analyzer applied to the detection of urinary tract infection.Methods 260 cases underwent specimen detection in our hospital from March 2014 to March 2015 were selected as the subjects.The result of white blood cell count, bacteria count and nitrites test were compared with that of bacterial culture.Results①Bacterial count sensitivity (50.76%), specificity (77.83%), positive predictive value (60.18%) and negative predictive value (82.69%) compared to the three joint sensitivity (80.01%), specificity (82.21%), positive predictive value (64.32%) and negative predictive value (86.51%) was significantly lower, with significant difference (P<0.05);②White blood cell count in the related aspects compared with the three combined index has significant difference (P<0.05);③Nitrite in the related aspects compared with the three combined index has significant difference(P<0.05).Conclusion For the detection of urinary tract infection, urine dry chemistry analyzer combined with urine formed element analyzer has high sensitivity, which can ensure the detection results be scientific and accurate, improve the work efficiency as well as exclude urinary tract infection to a larger extent, so it is worthy of wide promotion and application in clinical practice.
收稿日期:(2015-06-26)
Clinical Study of the Effect of Urine Dry Chemistry Analyzer Combined with Urine Formed Element Analyzer on the Detection of Urinary Tract Infection
ZHAO Fei
Clinical Laboratory, No.97 Hospital of PLA, Xuzhou, Jiangsu Province, 221009 China
[Key words]Urinary tract infection; Urine dry chemistry analyzer; Urine formed element analyzer
尿路感染是临床的常见疾病,在尿液中检测到细菌白细胞、红细胞等有形成分是临床拟诊尿路感染时有效的客观依据,它们在病情诊断、病情进展和预后等方面的研究判断具有重要意义[1-3]。该研究对该院在2014年3月—2015年3月收治的260例尿路感染住院患者尿液联合应用Iris iQ200尿沉渣分析仪和URIT-1500尿液干化学分析仪进行尿液标本检测,现报道如下。
1 资料与方法
1.1一般资料
整群选取2014年3月—2015年3月期间在该院收治的260例标本检测患者作为研究对象,其中男性患者120例,女性患者140例,年龄在23~58岁之间,平均年龄41岁,未用抗生素前留晨尿进行检验。
1.2试剂和仪器
尿沉渣分析仪器选择美国Iris iQ200尿沉渣分析仪及其配套试剂和质控品;……