APP下载

浅析反梁结构屋面裂缝产生原因分析及加固

2012-10-15黄洁

城市建设理论研究 2012年20期

黄洁

[摘要] 屋面漏水是建筑工程中常见的质量通病之一,严重影响使用效果,必须采取积极有效的对策,加强相应的加固措施。本文通过对某教学反梁结构屋面裂缝楼的检测与鉴定,分析了反梁屋面中裂缝产生的原因,指出了反梁屋面设计中的注意事项,介绍了相应的加固措施,希望有关结论可为此类屋面的设计和加固处理提供参考。

[关键词] 反梁结构屋面;裂缝原因;加固措施

Abstract: Roof leakage is a common problem of the construction works quality, seriously affect the results, we must take positive and effective measures to enhance the reinforcement measures. In this paper, the detection and identification of cracks in floor on the roof of a teaching anti-beam structure, analysis of the causes of cracks in the anti-beam roof, pointed out the precautions in the design of anti-beam roof, reinforcement measures and hope that the conclusion can be provide a reference design and reinforcement of such roof.Key words: anti-beam structure of the roof; Cracks; reinforcement measures.

中图分类号:F253.3文献标识码:A 文章编号:

一、工程概况

湖南某学院1#、2#教学楼为框架与砖砌体混合结构,基础为柱下独立基础和墙下砖砌条形基础。该两栋教学楼平面呈长方形,长度为72.54m,宽度为10.14m,六层,房屋总高度21.9m,在长度方向中部设置一道伸缩缝。顶层1~7轴、18~24轴为阶梯教室,其屋面为现浇混凝土反梁结构。该工程2003年12月完工,2004年6月发现四间阶梯教室屋面板底面在跨度中间部位出现沿开间方向的裂缝,裂缝没有贯穿反梁底面,而是在反梁底面处断开,裂缝宽度为0.15~0.25mm,裂缝呈继续增加的趋势。裂缝分布如图1所示。

图1 教学楼顶层裂缝分布

二、检测结果

根据《回弹法检测混凝土抗压技术规程》(JGJ/T23-2001),采用ZC3-A型回弹仪进行批量评定,阶梯教室屋面构件现龄期混凝土强度推定值为21.9MPa,能够达到设计混凝土强度等级要求;采用卷尺和游标卡尺检测屋面梁的截面尺寸和屋面板厚度,每间阶梯教室抽查4处,屋面梁截面尺寸和屋面板厚度基本符合设计要求;使用钢筋位置测定仪(配合局部凿开检测)每间阶梯教室抽查4处,屋面梁和屋面板的钢筋配置符合设计要求。……