高层建筑地下室防水工程施工质量控制探讨
2012-10-15李卉
李卉
摘要:近年来,一些地下结构防水工程质量较差,导致了地下室漏水事件经常发生。地下混凝土结构长期渗水,会破坏地下混凝土结构的整体性,从而影响了主体结构的稳定性和使用寿命。本文阐述了高层建筑地下室渗漏水产生的原因和防水工程的质量控制,并且提出了对出现渗漏所采取的处理措施,从根本上控制地下室防水工程的质量,做好高层建筑物地下结构的防水。
关键词:高层建筑;地下室防水;质量控制
Abstract: in recent years, some of the underground structure waterproof project quality is poorer, led to the basement leaking incident occurred. Underground concrete structure long-term seepage and undermine the integrity of the underground concrete structure, which affect the main structure of the stability and long service life. This paper expounds the high-rise building the causes of the leakage of the basement and waterproof project quality control, and puts forward to appear the leakage treatment measures taken to fundamentally control of waterproofing of basement project quality, completes the high-rise buildings underground structure of the waterproof.
Keywords: high building; The basement waterproof; Quality control
中图分类号:TU97文献标识码:A 文章编号:
1 地下室工程渗漏水的原因
1.1 工程设计方面
没有意识到影响混凝土抗渗性能的多种因素, 认为地下钢筋混凝土结构有一定厚度就能够满足结构防水要求,导致后期混凝土碳化加速钢筋的锈蚀程度等,使得结构产生裂缝而出现渗漏。设计地下室时防渗标高不够, 没有考虑到自然条件的实际情况, 多雨季节出现的地下水位抬高,防水标高以上部分出现内渗漏。地下室墙与底板交接处的阴角设计成直角,比坡角或者圆弧角容易漏水。
1.2施工方面
若施工方案的编制、材料的选择、施工程序等各环节控制不好,都有可能导致渗漏。施工前没有对混凝土设计配合比抗渗性能进行试验,抗渗混凝土配合比不合理,会影响实际抗渗性能。混凝土浇注前没有计算进行供料速度与施工浇注需求速度關系, 造成因供不应求而不能连续浇注, 使得前后浇注混凝土之间形成冷缝, 从而产生渗漏通道。……